If the vacuum pump is delivered without drive motor, a drive motor
must be mounted according to the following specifications:
Motor type
3ph motor - synchronous motor
Number of poles
2
Size
BG 100
COBRA NC 0100 B
Size
BG 132
COBRA NC 0200 B
Size
BG 132
COBRA NC 0300 B
BG 160 with adapter flange
Fixing type
Flange, IM 3001 (IM B5)
Assembly position
Shaft horizontal
Network frequency
max. 50 Hz, resp. 60 Hz. See nameplate of the va-
cuum pump
Frequency converter
Authorized for all vacuum pumps with direct coo-
running
ling system
Network voltage
Customised
Protection type
Customised
Explosion protection
In regard to its explosion protection, the motor
must have at least the same protection level as the
vacuum pump for the outside area ("outside" (o)).
See nameplate of the vacuum pump. A higher pro-
tection level, e.g. for the explosion group or the
temperature class, can also be used.
The highest permissible motor power is regulated according to the
operating frequency and the operational mode, see table below:
Highest permissible
motor power for di-
COBRA
Frequency
rect network connec-
tion
50 Hz
NC 0100 B
60 Hz
50 Hz
NC 0200 B
60 Hz
NC 0300 B
50 Hz
Installation
Seite/ Page/ Page 16
Highest permissible
motor power using a
frequency converter
3 kW
4 kW
4 kW
7,5 kW
5,5 kW
7,5 kW
7,5 kW
11 kW
7,5 kW
11 kW

Motor mounting instructions

Before the mounting of the motor, the coupling must be installed
between the motor and the vacuum pump. Respect the Installation and
Operating Instructions of the coupling. Regarding the explosion
protection, the coupling must show at least the same protection degree
like the vacuum pump for the outside category ("outside" (o)). See the
nameplate of the vacuum pump. Concerning the explosion group and
the temperature class, a higher protection degree can be applied. But
only Busch original couplings should be used.

Motor mounting

The motor is fixed to the center flange of the pump thank to 4 screws.
NC 0100...0300 B, Cat. 1