Ergänzung der Installations- und
Betriebsanleitung
Supplement of Installation and
Maintenance Instructions
Supplément au Manuel d'Installation
et de Maintenance
Vakuumpumpen
Vacuum Pumps
Pompes à Vide
in Übereinstimmung mit der EG-Richtlinie 2014/ 34/ EU
in compliance with the European Directive 2014/ 34/ EU
en accord avec la Directive Européenne 2014/ 34/ UE
COBRA NC 0100 ¼ 0300 B
Gasgruppe/ Gas group/ Groupe de gaz IIC
für/ for/ pour ATEX Category 2
Ateliers Busch S.A.
Zone industrielle
2906 Chevenez
Schweiz / Switzerland / Suisse
0870562556/-0004/
060521 / Originalbetriebsanleitung - Original instructions - Manuel original
Änderungenvorbehalten - Modifications reserved - Sous réserve de modifications

Publicité

Table des Matières
loading

Sommaire des Matières pour BUSCH COBRA NC 0100 B

  • Page 1 Directive Européenne 2014/ 34/ UE COBRA NC 0100 ¼ 0300 B Gasgruppe/ Gas group/ Groupe de gaz IIC für/ for/ pour ATEX Category 2 Ateliers Busch S.A. Zone industrielle 2906 Chevenez Schweiz / Switzerland / Suisse...
  • Page 2: Table Des Matières

    Raccordement électrique/ Contrôles ... . . 22 Inhaltsverzeichnis/ Table of Instructions de montage du moteur....23 Montage du moteur ....23 Contents/ Table des matières Mise en service .
  • Page 3: Deutsch

    ACHTUNG Einleitung Angaben in diesem Kapitel ersetzen doppelte Angaben der Standard-Installations- und Betriebsanleitung! Herzlichen Glückwunsch zu der Vakuumpumpe von Busch. Mit aufmerksamer Beobachtung der Bedürfnisse der Anwender, mit Anwendungsbereich Innovation und beständiger Weiterentwicklung liefert Busch moderne Vakuum- und Drucklösungen weltweit.
  • Page 4: Betrieb

    l am saugseitigen Spülgasanschluss nicht explosives Gas zuführen l am saugseitigen Spülgasanschluss nicht explosives Gas zuführen Spülgasanschluss Spülgasanschluss l Nicht explosives Gas-Volumenstrom : l Nicht explosives Gas-Volumenstrom : u NC 0100 B : ³ 25 Liter/ min u NC 0100 B : ³ 25 Liter/ min u NC 0200 B : ³...
  • Page 5: Störung

    Temperaturklassen in Abhängigkeit vom Kühlsystem und der europäischen Richtlinie 2014/ 34/ EU. maximalen Motorbetriebsfrequenz entnehmen: Die Vakuumpumpen sind mit einer der folgenden Explosionsschutzkennzeichnungen versehen: Durchlaufkühlsystem Umlaufkühlsystem Kühlsystem COBRA NC 0100 B Max. Einstellbare Max. Mo- Einstellbare Motor- Inside Ex h...
  • Page 6: Installation

    50 Hz T3 (i/o) 50 Hz elektrischen oder elektromagnetischen Interferenzen gestört wird. Im Zweifelsfall, wenden Sie sich an Ihre Busch Vertretung Die Pumpe kann bei falscher Drehrichtung erheblich beschädigt Installation werden. Zur Änderung der Drehrichtung müssen 2 Phasen des Motors Vakuumsystem getauscht werden.
  • Page 7: Motor-Montagevorschrift

    Betriebsfrequenz l Umgebungstemperatur Folgende Tabellen zeigen die erforderliche Einstellung (Position) des Thermostatventils bei unterschiedlichen Kühlmedien. Thermostatventileinstellung der COBRA NC 0100 B Betriebsfrequenz 50/ 60 Hz, T -20 °C bis +40 °C, Gasein- Umgebung trittstemperatur < 60 °C Temperaturklasse (o) outside T4 Kühl-...
  • Page 8: Wartung

    Reinigung aussenliegender Teile wie Lüfterhaube und Kühler Andere Montage- sowie Reparatur- und Wartungsarbeiten müssen ACHTUNG durch Fachmonteure des BUSCH-Kundendienstes durchgeführt werden. Die Wartung der Pumpe entnehmen Sie bitte der beiliegenden Installations- und Betriebsanleitung COBRA NC 0100 ¼ 0300 B.
  • Page 9: Eu-Konformitätserklärung

    EU-Konformitätserklärung Konformitätserklärung und die auf dem Typenschild angebrachte CE-Kennzeichnung gelten für die Maschine im Rahmen des Lieferumfangs von Busch. Die alleinige Verantwortung für die Ausstellung dieser Konformitätserklärung trägt der Hersteller. Wird die Maschine in eine übergeordnete Maschinenanlage integriert, muss der Hersteller dieser Anlage (ggf. das die Anlage betreibende Unternehmen) die übergeordnete Maschine bzw.
  • Page 11: English

    Introduction The indications noted in this chapter replace the indications of the standard installation and operating manuals! Congratulations on your purchase of the Busch vacuum pump. With watchful observation of the field’s requirements, innovation and steady Area of application development Busch delivers modern vacuum and pressure solutions worldwide.
  • Page 12: Inerting Process

    Inerting process: l Feed non explosive gas through the flushing gas connection, suction side l Close the pump inlet (suction valve MV1) l Feed non explosive gas through the flushing gas connection, suction side Flushing gas connection Flushing gas connection l Non explosive gas volume flow : u NC 0100 B : ³...
  • Page 13: Trip Procedure

    Max. mo- Max. mo- Temperature Tempera- Type tor fre- tor fre- class ture class COBRA NC 0100 B quency quency Inside Ex h 50 Hz T4 (i/o) T3 (i/o) 60 Hz T3 (i)/ T4(o)
  • Page 14: Installation

    The filter or the screen should have a mesh size £ 0.2mm side area ("outside" (o)). See nameplate of (DN50 flange: Busch Part No. 0534 562 610). the vacuum pump. A higher protection le- Connect the screen to earth via the earthing M6 thread.
  • Page 15: Motor Mounting

    The following running values have a direct influence on the checked certified for the gaz group IIC. Concerning the temperature class, a temperatures: higher protection degree can be applied. But only Busch original l Temperature of the gas entry (< 60 °C) couplings should be used.
  • Page 16: Maintenance

    Cleaning the external parts such as fan cover and cooler CAUTION Other work such as dismantling or rebuilding jobs as well as repair and maintenance work may only be carried out by BUSCH customer service Information on the maintenance of the pump can be found in the engineers.
  • Page 17: Eu-Declaration Of Conformity

    EU-Declaration of Conformity This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.
  • Page 19: Français

    Domaine d’application ainsi aux besoins des utilisateurs, Busch fournit des solutions de vide et de pression modernes dans le monde entier. Les pompes à vide de la gamme COBRA NC 0100 ¼ 0300 B peuvent aspirer des mélanges de gaz et de vapeurs explosives de Zone 1 et du...
  • Page 20: Procédure D'inertisation

    Procédure d’inertisation: l Introduire du gaz non explosif par le raccord du gaz de rinçage côté aspiration l Fermer l’entrée de la pompe (vanne d’aspiration MV1) l Introduire du gaz non explosif par le raccord du gaz de rinçage côté aspiration Raccord gaz de rinçage Raccord gaz de...
  • Page 21: Dysfonctionnement

    Les pompes à vide sont pourvues de l’un des marquages suivants de classes de températures dépendant du système de refroidissement et la protection contre les explosions: fréquence maximale de fonctionnement du moteur: COBRA NC 0100 B Inside Ex h Système de...
  • Page 22: Installation

    En cas de doute, prendre contact avec votre représentant Busch. T4 (i/o) 50 Hz La pompe peut être gravement endommagée si son sens de rotation NC 0300 B T3 (i/o) 50 Hz est contraire.
  • Page 23: Instructions De Montage Du Moteur

    Le tableau suivant donne pour différents réfrigérants des valeurs indicatives (position) pour le réglage de la vanne thermostatique. Valeurs indicatives pour le réglage de la vanne thermostatique de la pompe COBRA NC 0100 B Fréquence de fonctionnement 50/ 60 Hz, T -20 °C à +40 Environnement °C, Temperature entrée des gaz <...
  • Page 24: Maintenance

    Maintenance Valeurs indicatives pour le réglage de la vanne thermostatique de la pompe COBRA NC 0200 B Généralités Fréquence de fonctionnement 50/ 60 Hz, T -20 °C à +40 Environnement °C, Temperature entrée des gaz < 60 °C Classe de temperature (i) inside T3 ATTENTION Classe de...
  • Page 25 Tout autre travail de montage ainsi que les travaux de réparation et d’entretien doivent être entrepris par des monteurs spécialisés du service après-vente BUSCH. AVERTISSEMENT Tous les travaux de nettoyage doivent toujours être effectués avec un chiffon humide, afin d’éviter une charge électrostatique et une décharge d’étincelles.
  • Page 27: Déclaration Ue De Conformité

    Cette Déclaration de Conformité ainsi que la marque CE apposée sur la plaque constructeur attestent de la validité de la machine dans le cadre de la livraison Busch. La présente déclaration de conformité est établie sous la seule responsabilité du fabricant.
  • Page 28 Chile Israel Portugal United Arab Emirates info@busch.cl service_sales@busch.co.il busch@busch.pt sales@busch.ae China Italy Romania United Kingdom info@busch-china.com info@busch.it office@buschromania.ro sales@busch.co.uk Colombia Japan Russia info@buschvacuum.co info@busch.co.jp info@busch.ru info@buschusa.com Czech Republic Korea Singapore info@buschvacuum.cz busch@busch.co.kr sales@busch.com.sg www.buschvacuum.com 0870565556/-0004_DE_EN_FR / © Ateliers Busch S.A.

Ce manuel est également adapté pour:

Cobra nc 0200 bCobra nc 0300 b

Table des Matières