Adjustment - Tractel tirak T 1000 Manuel D'installation Et De Manutention Original

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and operating manual
DIN 15020, Sheet 2) or typical rope defects are present, see
Fig. 13. Determining the rope diameter: See Fig. 9.
Design of the rope
Rotation-
resistant
[mm]
Number of visible broken wires in the
outer strands over a length of 30 x rope's
nominal diameter.
6
8
10
9
10
10
8
14
10
Table 7
Implementation:
See
' 12 Dismantling'
' 9.3 Assembly' on page 11.
Renewing rope tips
Send the rope to TRACTEL Greifzug GmbH or an lifting equip-
ment service company authorized by TRACTEL Greifzug GmbH
and have the tip replaced.
Power supply and control cables
The cables must be replaced by an electrician if any damage has
been caused to the insulation or the cable connectors.
Hoist
DANGER!
Danger of falling and danger from falling objects due to
slippery or damaged ropes or brake failure and malfunc-
tions!
Might result in severe injuries or even death!
Cleaning the rope or products in contact with the rope
using high pressure cleaners is prohibited! Moisture will
result in malfunctions and damage to the motor, brake
and the electrical equipment.
Dirt on the wire rope will result in premature wear or the
corrosion of the wire rope, rigging and hoist.
See the separate maintenance instructions provided for trained
personnel.
Motor, gearbox and brake
The motor, gearbox and brake are maintenance-free until the
number of permitted running hours are realized (general over-
haul).
EN-20
5 x 19
5 x 26
[mm]
8
5,9
8
11
7,5
8
8,5
11
9,3
11
13,1
on
page 17
Clean the outside if heavily soiled.
Keep the brake free of oil and grease.
Traction sheave external teeth
(model series X 3050)
Specification of grease, see ' 4.4 Operating fluids' on page 8.
Apply the grease gun to the lubrication nipple (1), see
Fig. 15.
Lubricate the lubrication nipple with 3–5 pumps (approx.
5 cm
).
3
Let the hoist run for approximately two seconds in the UP-
WARD and DOWNWARD directions.
Lubricate the lubrication nipple with 3–5 pumps (approx.
5 cm
).
3

15.5 Adjustment

Adjusting the load limiting device
and
Risk of being injured by falling objects!
Might result in severe injuries or even death!
The load limiting device may only be implemented by
personnel authorized by the system manufacturer or
TRACTEL Greifzug GmbH.
Observe the details in this instruction manual.
Always abide by the details given in the order specifica-
tions for special versions.
Hoists with a load bearing capacity of 1,000 kg or greater are
equipped with a mechanical load limiting device. Hoists with a
load bearing capacity up to 1,000 kg can be optionally equipped
with an electrical or a mechanical load limiting device.
Hoists fitted with mechanical load limiting devices cannot normal-
ly be set up to activate with an overload that is less than 90% of
the hoist's maximum working load.
The hoist's load limiting device has been set up in the factory to
activate with a maximum permitted overload of 125% of the
maximum working load.
The maximum overload must be lifted in order to set the load
limiting device.
Overload = maximum operating load + 25 %
Adjusting the mechanical load limiting device
Model series X 300 to X 1530
See Fig. 17.
Only load load lifting equipment with the calculated overload.
Raise the load.
The load limiting device must react and stop the UP travel of
the hoist within the first 10 cm.
DANGER!
G932.4 - 09/2015

Publicité

Table des Matières
loading

Table des Matières