The air inlets / outlets at the external unit and
the air distributor must not be obstructed
under any circumstances. This is essential
in order to ensure that your device operates
correctly.
In order to avoid damage to the compressor,
no uphill or downhill slopes with an incline of
more than 8 % must be driven on when the
device is being operated while driving (e.g.
with generator or voltage converter).
Do not operate the device in cooling mode
for long periods with the vehicle at an an-
gle, since the condensation that is produced
may not be able to run away and may pen-
etrate the vehicle if the circumstances are
unfavourable.
For problem-free operation and in order to
avoid damage, the supply voltage must al-
ways come from a source with a sine wave
curve (e.g. voltage converter, generator) and
without voltage spikes.
When the vehicle is being cleaned it must be
ensured that no water gets into the device
when spraying with a high-pressure cleaner,
for example (do not spray directly into the
openings of the device).
Hot cleaners and steam cleaners must not be
used.
The condensation traps must be clear at all
times during operation.
Notes on using air conditioning systems
The air conditioning system is designed for
power input of up to 2.8 A. You should still
check whether the camp site has adequate
fuse protection (min. 4 A) before starting the
equipment up.
Park the vehicle in the shade if possible.
Darkening with blinds reduces the amount of
heat insolation.
Clean your roof at regular intervals (dirty roofs
heat up more than clean roofs).
Ventilate your vehicle well before starting the
equipment in order to remove accumulated
warm air from the vehicle.
In order to obtain a healthy room climate, the
difference between the inside and outside
temperatures should not be too great. The
recirculated air is cleaned and dried during op-
eration. A pleasant room climate is produced
by drying the moist air, even with small tem-
perature differences.
Keep all doors and windows closed during
cooling operation so that no condensation
build-up occurs at the air distributor.
For faster cooling:
– Move fan level to high,
– Move front / rear air distribution to centre
position,
– Set floor / ceiling air distribution to ceiling.