Tableau 21 – Groupe Motor Protection (Continued)
Puissance
Puissance
réactive – (BA)
apparente (BA)
Motor Fault Enable
Motor Fault Enable
Motor Alarm
Motor Alarm
Enable
Enable
Motor Restart
Motor Restart
Enable
Enable
-MVAR Ov F Level
MVA Ov F Level
-MVAR Ov F Delay
MVA Ov F Delay
-MVAR Ov A Level
MVA Ov A Level
-MVAR Ov A Delay
MVA Ov A Delay
+MVAR Un F Level
MVA Un F Level
-MVAR Un F Delay
MVA Un F Delay
-MVAR Un A Level
MVA Un A Level
-MVAR Un A Delay
MVA Un A Delay
Fréquence réseau (BA)
Starter Fault Enable
Starter Alarm Enable
Starter Restart Enable
Frequency High F Level
Frequency High F Delay
Frequency High A Level
Frequency High A Delay
Frequency Low F Level
Frequency Low F Delay
Frequency Low A Level
Frequency Low A Delay
Paramètres du groupe Motor Protection
PF en avance
PF en retard (BA)
(BA)
Motor Fault Enable
Motor Fault Enable
Motor Alarm
Motor Alarm
Enable
Enable
Motor Restart
Motor Restart
Enable
Enable
Lead PF F Level
Lag PF F Level
Lead PF F Delay
Lag PF F Delay
Lead PF A Level
Lag PF A Level
Lead PF A Delay
Lag PF A Delay
Lead PF F Level
Lag PF F Level
Lead PF F Delay
Lag PF F Delay
Lead PF A Level
Lag PF A Level
Lead PF A Delay
Lag PF A Delay
Maintenance
Motor Fault Enable (BA)
Motor Alarm Enable (BA)
Motor Restart Enable (BA)
PM Hours (BA)
PM Starts (BA)
Time to PM (MBA)
Starts to PM (MBA)
Starts per Hour (MBA)
Publication Rockwell Automation 1560F-UM001A-FR-P – June 2019
Déséquilibre de
Déséquilibre de
tension (BA)
courant (BA)
Starter Fault Enable Motor Fault Enable
Starter Alarm
Motor Alarm
Enable
Enable
Starter Restart
Motor Restart
Enable
Enable
Current Imbal F
Level
Voltage Unbal F
Current Imbal F
Level
Delay
Voltage Unbal F
Current Imbal A
Delay
Level
Voltage Unbal A
Current Imbal A
Level
Delay
Voltage Unbal A
Delay
Historique (MBA)
Redémarrage (BA)
Fault 1
Motor Restart Enable
Fault 2
Starter Restart Enable
Fault 3
Restart Attempts
Fault 4
Restart Delay
Fault 5
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Programmation
Chapitre 4
THD – tension
THD – courant
(BA)
(BA)
Starter Fault Enable Motor Fault Enable
Starter Alarm
Motor Alarm
Enable
Enable
Starter Restart
Motor Restart
Enable
Enable
THD I F Level
THD V F Level
THD I F Delay
THD V F Delay
THD I A Level
THD V A Level
THD I A Delay
THD V A Delay
Rotor bloqué
(BA)
Motor Fault Enable
Motor Alarm
Enable
Motor Restart
Enable
Locked Rotor F
Level
Locked Rotor F
Delay
Locked Rotor A
Level
Locked Rotor A
Delay
OverCurrent LVL
111