8
Technical data
Power supply device
Power supply PCB
Fuse protection
Protection type
Protection class
Compressed air supply
Inputs
Versions 182603 and 182604
Outputs Version 182603
Version 182604 auxiliary
Maximum overall performance of all
connected pumps
Installation height
Ambient temperature
Dimensions / weight
Because of the company's policy of continuous improvements to its products, we reserve
the right to make changes without notice.
417101375_Connexx.doc
float switch lifting vessel terminal 18 – 19; zero-potential Reed contact
external enable signal
(enable input)
alarm X1, 3,4,5, change-over contact, max. 30 V, DC, 5A
empty signal LL1/LL2 X1, 6,7,8, change-over contact, max. 30 V, DC, 5A
pump enable X1, 9,10,11, change-over contact, max. 30 V, DC , 5A
lifting vessel X1, 12,13, output, 24 V, DC, max. 7,2 W, min. 3,6 W
valve container 1 X1, 14,15, output 24 V, DC, max. 7,2 W, min. 3,6 W
valve container 2 X1, 16,17, output 24 V, DC, max. 7,2 W, min. 3,6 W
continuously operating approx. 450 l/h (rotary pump)
oscillatory operation approx. 210 l/h (diaphragm pump)
Version 182603 410 x 335 x 150
Version 182604 650 x 335 x 155
Version 282603
(see accessories 9.2)
230 V, AC, 50/60 Hz
24 V, AC, 15 VA, 50/60 Hz
2 A time-lag; 5 x 20 mm microfuse
IP 65
II
3.5 - 6 bar (dynamic)
terminal 20 – 21; zero-potential contact
approx. 1 m above container top edge
lifting vessel higher than dosing pumps
10° to 40°C, no direct insulation
H x W x D (mm)
/
kg
/
approx. 4,6 kg
/
approx. 7,3 kg
265 x 295 x 155
/
approx. 2,7 kg
- 53 -
Rev. 11-02.10