SICE S 63 Manuel D'instructions page 64

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

for approximately 3 seconds to indi-
cate that the procedure described in
step 7 must be repeated correctly. If
the angle selected is less than 120°,
the machine immediately displays the
value of weight P2. The LED
remains on to indicate that the "Hidden
Weight" programme is active.
Figure 16D. Hidden Weights: Incorrect P2
weight position.
9 Manually turn the wheel, the two
unbalance values calculated are dis-
played in alternation on the display
regarding the outer side as the angular
position of the wheel changes.
10 Apply each of the two balancing
weights as described in the chapter
"ALU 1P, 2P Programmes".
11 Once the Hidden Weights programme
procedure is complete, you may con-
tinue working with any other programme.
The HIDDEN WEIGHT function is combined
with the SHIFT PLANES function to allow
balancing weights which are multiples of 5
grams to be used.
Standard ALU Programmes
(ALU 1, 2, 3, 4, 5)
The standard ALU programmes allow for the
various modes of application of the weights
(Fig. 12) and supply correct unbalance
values maintaining the settings of the rated
geometric alloy wheel data.
- Press the
the LED corresponding to the ALU pro-
gramme illuminates.
64
- Press the
- Set the rated geometric data.
If the values of the diameter and of the
distance between the balancing planes,
recalculated on a statistical basis starting
from the rated geometric data of the wheel,
exceed the normally accepted interval
stated in the TECHNICAL DATA section,
the "A Alu" message is displayed.
- Proceed as described for dynamic balanc-
- For the application of the balancing
IMPORTANT: in ALU1 and ALU2 pro-
grammes the unbalance displayed by the
machine on the outer side refers to the
adhesive weight centre of gravity at the shaft
assembly bearing flange, see figure 16e.
and keys until
Some slight residual unbalances may
remain at the end of the test spin due to
the considerable difference in shape that
may be found on rims having the same
as necessary to confirm the selection of
the Alu programme desired (the corre-
sponding balancing planes are highlighted
on the rim shown on the display).
ing.
weights, refer to the paragraph "SELEC-
TION OF ADHESIVE WEIGHTS APPLICA-
TION POSITION".
button as many times
16e
User manual S 63

Publicité

Table des Matières
loading

Table des Matières