Unit
· Grasp cord by plug to remove from outlet. DO NOT pull or yank on the cord itself. It may cause a wire disconnection or
malfunction.
· Care should be taken not to place the AC Cord near a gas burner. Never attempt to repair a burned motor cord. Always
replace it with a new cord.
· Prior to use, always check for vibration, noise and overheatin, If any abnormalities are detected, stop using immediately
and contact your authorized NSK Dealer.
· Be careful not to spill water onto the Unit as this may result in a fire or an electric shock due to a short-circuit.
Motor,Handpieace(Option)
· Do not use this product under strong stress for long time. It is cause overheat
· Do not connect or disconnect the cord until the drive motor has completely stopped.
· Do not connect / disconnect the handpiece during operation.
· Verify that the Speed Control Switch is adjusted within the allowable speed before use.
· Connect only 4-hole, 5-hole or 6-pin tubing.
· Air Requirements: dry, free from contamination and oil. Use a compressor with a dry air system. Install an air filter if
necessary. Blow out the lines before installation.
· Do not Autoclave (or any other high temperature Sterilization) Control Box, AC Adapter, Motor Cord.
· The user shall be responsible for operation, maintenance and operation.
· The operator is responsible for correct operational control, maintenance and inspection.
· Surface temperature shall be more than 60 ºC without using a coolant air, to avoid this event, be sure to use coolant air.
· During rotation, the motor and the motor cord may affect computer and LAN cable. Noise could be heard during operation
near a radio receiver.
· After treatment, immediately turn off the power switch and shut off the air supply.Remove the power cord if the unit box is
not to be used for a long time.
· Responsibility for operating and maintaining Medical Devices belongs to the user.
· Store the system in the place where the temperature is at -0-60°C (4-40°F), humidity at 0-85%RH, atmospheric
pressure at 500-060 hPa, and the system is not subject to air with dust, sulfur, or salinity.
1. Specification

Control Box

Model
Rated input
Drive Air Pressure
Dimensions
Motor
M o d e l
Rotation Speed
Dimensions
Water Supply
Chip Air
Coolant Air Supply
C A U T I O N
NLX nanoU ( NE278 )
AC28V 50/60 Hz
0.4MPa ( 4.0kgf/cm
)
2
W27 x D49 x H54 mm
NLX nano
2,000 - 40,000 min
-
DØ22 x H70 mm
More than 65 mL/min ( 0.2MPa )
More than .5 L/min ( 0.2MPa )
More than 6.5 NL/min ( 0.2MPa )
N O T I C E
AC Adaptor
Model
Rated input
Output
Fuse
Dimensions
2
AC Adaptor ( NE80 )
AC20V 50/60Hz 4VA
AC230V 50/60Hz 4VA
AC28V .3A
AC20V TR5-T C 250V
9372 T.6A
AC230V TR5-T C 250V
800mA
W00 x D78 x H64 mm