11. Technical data

Ambient conditions
Storage temperature:
Ambient temperature:
Relative humidity:
Sauna control unit
Dimensions:
Switched voltage / three-phase 3N:
Frequency:
Contact rating of heater AC 1:
Switched current per phase of heater AC 1:
Min. / max. input power:
Protection type (protected against jets of water):
Temperature setting range:
Connection to the mains supply as fi xed wiring (fi xed connection)
Light
Contact rating:
Fuse:
Thermal safety
Heater sensor with excess temperature fuse (139 °C shut-off temperature)
Automatically switches off after 6 hrs. (heating period limit)
Single sensor system with temperature sensor above the heater
Connection cables
Power supply cable:
Heater supply cable:
Sensor wires:
Light wire:
Temperature resistance
Heater, light and sensor wire
Power supply cable
WORLD OF WELLNESS
p. 17/18
-25 °C to +70 °C
-10 °C to +40 °C
max. 95%
236 x 195 x 90 mm
400 V
50 Hz
3 x 3 kW
13 A
1.3 / 6.3 VA
IP X4
+40 °C to +125 °C
100 W
1A T
min. 5 x 2.5 mm²
min. 1.5 mm²
min. 0.75 mm²
min. 1.5 mm²
min. 150 °C
min. 90 °C
En