ACKNOWEDGING ERRORS VIA THE KEYBOARD
Press any button.
The Alarm message remains on the display as long as the alarm conditions
are present. The device then switches to normal operation.
AUTOMATIC ACKNOWLEDGEMENT OF THE ERROR
Message PFo and PFc - Room sensor error
•
After approx. 30 seconds or once the error has been cleared, the
message will be acknowledged automatically. Check the connections
before any replacement of the sensor.
Messages HA/LA - High/Low temperature alarm
•
The messages disappear automatically as soon as the normal temperature
range is reached again or if defrosting starts.
•
External alarms EAL and BAL are acknowledged after deactivation of the
digital input.