Safety Information For The Installer - Sentiotec PRO-C3 Instructions Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 110
Instructions for installation and use

2.2. Safety information for the installer

● Installation may only be performed by a qualified electrician or
similarly qualified person.
● Work on the sauna control unit may only be performed when the
power has been disconnected.
● An all-pole disconnecting device with full cut-off compliant with
overvoltage category III must be fitted on-site.
● The sauna control unit must be installed outside the sauna room
at a height of approx. 1.70 m or in accordance with the rec-
ommendation issued by the sauna manufacturer. The ambient
temperature must be within a range spanning -10 °C to +40 °C.
● The heater sensor must be attached in a way that it is not af-
fected by a flow of air.
● The heater supply cable must have a minimum cross-section of
2.5 mm
2
and be temperature resistant up to 150 °C.
● Also comply with the regulations applicable at the installation
location.
● For your own safety, consult your supplier in the event of prob-
lems that are not explained in sufficient detail in the installation
instructions.
p. 7/54
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pro c3

Table des Matières