Instructions for installation and use
2. Important information for your safety
The sauna control unit K1 Next has been produced in accordance
with the applicable safety regulations for technical units. However,
hazards may occur during use. You should therefore adhere to the
following safety information and the specific warning notices in the
individual chapters.
2.1. Intended use
The sauna control unit K1 Next is used for operating and control-
ling sauna heaters in a private household in accordance with the
technical data. It may only be used for operating and controlling
3 heating circuits with a maximum heating capacity of 3 kW per
heating circuit.
Any use exceeding this scope is considered improper use. Improper
use can result in damage to the product, severe injuries or death.
2.2. Safety information for the installer
● Installation may only be performed by a qualified electrician or
similarly qualified person.
● Installing and connecting the sauna control unit may only be
performed when the power supply is disconnected.
● A three-phase shut-off device with a 3 mm contact opening must
be provided during installation. This is provided by the fuse.
● The sauna control unit must be installed outside the sauna room
at a height of approx. 1.70 m or in accordance with the recom-
mendation issued by the sauna manufacturer. The ambient
temperature must be within a range spanning -10 °C to +40 °C.
● The heater sensor must be attached in a way that it is not af-
fected by inflow of air.
WORLD OF WELLNESS
p. 4/18