3-7. Remote 14 Receptacle Information
A
A
J
J
K
I
B
C L N
H
M
D
G
F
F
E
E
*The remaining sockets are not used.
24 VOLTS AC
24 VOLTS AC
115 VOLTS AC
115 VOLTS AC
REMOTE
REMOTE
OUTPUT
CONTROL
A/V
AMPERAGE
AMPERAGE
Ref. ST-801 718
Ref ST-801 718
VOLTAGE
GND
GND
Socket*
Socket Information
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac con-
tactor control circuit.
C
Output to remote control; +10 volts dc in MIG
mode.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from re-
mote control.
M
Mode select.
N
Remote inductance control.
F
Current feedback; +1 volt dc per 100 amperes.
H
Voltage feedback; +1 volt dc per 10 arc volts.
G
Circuit common for 24 and 115 volts ac circuits.
K
Chassis common.
OM-188 422 Page 17