Remote 14 Receptacle Information And Connections; Remote 14 Socket Information; Connecting Input Power - Miller Maxstar 91 Manuel Du Propriétaire

Table des Matières

Publicité

3-5. Remote 14 Receptacle Information And Connections

3-6. Remote 14 Socket Information

*The remaining sockets are not used.

3-7. Connecting Input Power

OM-207 Page 12
1
2
A
J
K
I
B
C L N
H
M
D
G
F
E
4
3
Socket*
A
+15 volts dc.
B
Contact closure to A completes +15 volts dc contactor control circuit.
C
Output command reference; 0 to +10 volts dc depending on setting of
Amperage Adjustment control R4.
D
Remote control circuit common.
E
Input command signal (potentiometer wiper or 0 to +10 volts dc).
K
Chassis common.
Rear Panel
sb7.1 5/94 – ST-800 916 / Ref. S-0004-A / S-0750 / Ref. ST-141 127-B
Socket Information
2
1
1
Remote 14 Receptacle RC2
(See Section 3-6)
2
Keyway
3
Plug
4
Threaded Collar
To connect to receptacle, align
keyway, insert plug, and tighten
threaded collar.
1
115 VAC Cord/Plug
2
115 VAC Grounded
Receptacle
An individual branch circuit capable
of carrying 20 amperes, and pro-
tected by fuses or circuit breaker is
required. Recommended fuse or
circuit breaker size is 30 amperes.
Connect input power plug to proper
115 VAC receptacle.
ST-157 357-B

Publicité

Table des Matières
loading

Table des Matières