Removing Case And Measuring Input Capacitor Voltage - Miller Phoenix 456 CC/CV Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Phoenix 456 CC/CV:
Table des Matières

Publicité

5-3. Removing Case and Measuring Input Capacitor Voltage

Tools Needed:
5/16 in
Y Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.
1
1
2
3
+ lead to lower right
terminal, − lead to
upper right terminal
Turn Off welding power source, and
disconnect input power.
1
Outside Handle Screws
To loosen top, remove two outside
handle screws from both handles
and all side bolts.
2
Interconnecting Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on RC3 and RC5
as shown until voltage drops to near
0 (zero) volts.
Proceed with job inside unit. Rein-
stall cover when finished.
Ref. ST-801 718 / ST-801 536
OM-188 422 Page 25