115 Volts Ac Duplex Receptacle; Electrical Service Guide - Miller Phoenix 456 CC/CV Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Phoenix 456 CC/CV:
Table des Matières

Publicité

3-8. 115 Volts AC Duplex Receptacle

1

3-9. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size in AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size in AWG/Kcmil
Reference: 1993 National Electrical Code (NEC).
OM-188 422 Page 18
2
3
1
115 V 7 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 3-7).
2
Circuit Breaker CB1
3
Circuit Breaker CB2
CB1 protects 115 volts ac portion of
duplex receptacle and Remote 14
receptacle from overload.
CB2 protects 24 volts ac portion of
Remote
14
receptacle
from
overload.
Press button to reset breaker.
Ref. ST-801 524-A
400
31
45
10
264 (80)
10
S-0092J

Publicité

Table des Matières
loading