3-2. Weld Output Receptacles And Selecting Cable Sizes
Weld Output
Terminals
+
–
Output Receptacles
Output Receptacles
Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
3-3. Remote 14 Receptacle Information
A
J
K
K
I
I
B
C L N
N
H
H
C
M
D
G
F
E
*The remaining sockets are not used.
OM-2231 Page 12
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
10 – 60%
60 – 100%
Welding
Duty
Duty
Amperes
Cycle
Cycle
100
4
150
3
200
3
250
2
300
1
350
1/0
400
1/0
500
2/0
600
3/0
24 VOLTS AC
24 VOLTS AC
115 VOLTS AC
115 VOLTS AC
REMOTE
OUTPUT
CONTROL
AMPERAGE
VOLTAGE
150 ft
200 ft
(45 m)
(60 m)
4
4
3
3
2
1
2
1
1/0
1
1/0
2/0
1/0
2/0
3/0
2/0
3/0
4/0
2/0
3/0
4/0
3/0
4/0
2-2/0
4/0
2-2/0
2-3/0
Socket*
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac
contactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac
contactor control circuit.
C
Output to remote control; 0 to +10 volts dc, +10
volts dc in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from
remote control.
M
CC/CV select
F
Current feedback; +1 volt dc per 100 amperes.
A/V
A/V
H
Voltage feedback; +1 volt dc per 10 output recep-
tacle volts.
G
Circuit common for 24 and 115 volts ac circuits.
GND
K
Chassis common.
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 – 100% Duty Cycle
2
1
1/0
1/0
2/0
3/0
2/0
3/0
4/0
3/0
4/0
2-2/0
4/0
2-2/0
2-3/0
2-2/0
2-3/0
2-3/0
2-2/0
2-3/0
2-4/0
2-3/0
2-4/0
3-3/0
2-4/0
3-3/0
3-4/0
Socket Information
400 ft
(120 m)
1/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
3-3/0
3-4/0
S-0007-D