STOPPING THE ENGINE
STOP
For shutdown under normal conditions, proceed as
follows:
Break the welding process in course.
2 Break the production of a.c. auxiliary generation
dividing the loads or opening the GFI
(D).
Let the engine run with no load for a few minutes.
Turn the start key on the EP7 to the OFF position.
OFF
ON
START
EMER ENC
SHUT OWN
To stop the group in a dangerous situation, press
the emergency stop button (L5) (or turn the start
key (Q1) to the OFF position). To reset the knob,
turn it clockwise.
KHM 525 PS/PSX
M
22