Minimum clearance to combustible construction from appliance and vent surfaces:
Non-combustible Framing:
Top
Combustible Framing:
Sides, back and bottom of appliance
Top
Combustible Finishing:
Sides, bottom and top
Enclosure top
Recessed depth
Top, sides and bottom of vent pipe*
Ceiling
* HORIZONTAL VENT SECTIONS - A minimum clearance of 1" (25mm) at the bottom and sides and 2"
(51mm) at the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer
W010-1777 (supplied).
* VERTICAL VENT SECTIONS - A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).
6.1
INSTALLING STAND-OFFS
These appliances are supplied with two standoffs. For
convenience, the standoffs have been shipped fl at and located on
the top at the front. Before framing ensure the standoffs are bent
up and screwed into place ensuring a height of 4.5" (144mm).
NOTE: The information and dimensions in this section
represent the minimum clearances to combustible material.
It is best to frame your appliance after it is positioned and the vent
system is installed. Use 2x4's and frame to local building codes.
A steel header is required if using optional clean face surround.
- 0" to stand-offs if using optional clean face surround.
- 0" to rear.
- 3 1/2" (89mm) to stand-offs if using optional clean face
surround.
- 0" to appliance edge.
- 13 1/2" (343mm) to top of appliance.
- 25" (635mm)
- 2" (51mm)
- 54" (1372mm) from bottom of appliance.