38
6.4.2 HEARTH INSTALLATION
When installing to a hearth the appliance riser must create a minimum clearance of 3 3/8" (86mm) PLUS the
height of the hearth from the fi nished fl oor to the bottom of the appliance.
EN
CLEAN FACE SURROUND KIT
CLEANFACE SURROUND
FINISHED FLOOR
6.5
NON-COMBUSTIBLE FACING MATERIAL
FINISH
MATERIAL
TOP OF
APPLIANCE
WARNING: Non-combustible facing material may protrude from the top, and/or sides of this appliance,
as illustrated [up to a maximum of 6" (152.4mm)]. Greater than 6" (152.4mm) protrusions are considered a
W415-1132 / C / 08.20.13
STEEL
HEADER
(SUPPLIED)
STAND OFF
3 3/8"
3 3/8"
85mm
85mm
CLEARANCE
PLUS HEARTH
HEIGHT
NON-COMBUSTIBLE
FACING MATERIAL
4" (102mm)
2" (51mm)
0" (0mm)
6" (152mm)
4" (102mm)
2" (51mm)
mantel and must meet the combustible mantel requirements.
COMBUSTIBLE
MATERIAL
CEMENT BOARD
PANEL (SUPPLIED)
6 1/2" 165mm MIN
37 3/8"
949mm
PLUS
HEARTH
HEIGHT
CLEARANCE
SURROUND KIT
FIREPLACE
HEARTH
3 3/8"
RISER
HEARTH
85mm
CLEARANCE
FRONT OF
APPLIANCE
2" (51mm)
4" (102mm)
6" (152mm)
0" (0mm)
2" (51mm)
4" (102mm)
STEEL
HEADER
(SUPPLIED)
STAND OFF
FIREPLACE
RISER
3 3/8"
FINISHED FLOOR
85mm
PLUS HEARTH
HEIGHT
FINISH MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
71.4B