fi nishing
EN
10.4 installing non-combustible board
WARNING
!
•
The surface above the appliance gets very hot. If proper fi nishing materials are not used, cracking can occur.
1. Align the non-combustible panel against the appliance and secure in place with the drywall screws.
8"
(203mm)
Joint Compound where required
Joint compounds such as Durabond 90 and tapes that are resilient to heat and cracking should be used when
taping and mudding seams.
Setting tiles and grouting
We recommend you use tiles with a dry butt joint to be installed using a two-part mortar with an acrylic latex
additive, such as Mapei Kerabond/Kerlastic, to allow for slight movement in the normal operation of the appliance.
If grout is used between the tiles, a polymer-based grout, such as Mapei Ultracolour plus, is recommended.
Primer/Paint
For a painted surface, use a 100% acrylic latex primer and fi nish coat. Light coloured paints may discolour.
note:
Non-combustible panel shipped loose in carton (5
screws supplied).
48
W415-2920 / B / 04.26.22
42"