INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50 FOR VENTED GAS FIREPLACES
FOR INDOOR USE ONLY
SAFETY INFORMATION
WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
BGD36CFNTR &
BGD36CFNTRE
NATURAL GAS MODEL
BGD36CFPTR &
BGD36CFPTRE
PROPANE GAS MODEL
DANGER
!
HOT GLASS WILL CAUSE
DO NOT TOUCH GLASS UNTIL
NEVER ALLOW CHILDREN TO
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
BURNS.
COOLED.
TOUCH GLASS.
1.28G
W415-1345 / C / 02.14.17
EN
FR
PG
59

Publicité

loading

Sommaire des Matières pour Napoleon BGD36CFPTRE

  • Page 1 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com $10.00...
  • Page 2 TABLE OF CONTENTS NOTE: The camera icon indicates video tutorials are available as additional reference, visit http://mynapoleon.napoleonproducts.com/download/index/44/1 INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION 3.3.2...
  • Page 3 13.0 REPLACEMENTS 13.1 OVERVIEW 13.2 MILLIVOLT VALVE TRAIN ASSEMBLY 13.3 ELECTRONIC VALVE TRAIN ASSEMBLY 14.0 ACCESSORIES 15.0 TROUBLESHOOTING ELECTRONIC 16.0 TROUBLESHOOTING MILLIVOLT 17.0 WARRANTY NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. 1.0 INSTALLATION OVERVIEW See the sections “MINIMUM ENCLOSURE CLEARANCES”...
  • Page 4 2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND ARE PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5 DIMENSIONS 5" 127mm 38 1/2" 978mm 7" 34" 27" 686mm 178mm 864mm SAFETY BARRIER 8" 4" 24 1/4" 203mm 102mm 616mm GAS INLET 3" 76.2mm 40" 1016mm 15" 381mm 17" 432mm GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 6 7" (17mb) w.c. 13" (32mb) w.c. Manifold Pressure (Under Flow Conditions) 3.5" (9mb) w.c. 10" (25mb) w.c. MODEL DESIGNATIONS FUEL TYPE OPERATING SYSTEM BGD36CFNTR NATURAL MILLIVOLT NATURAL ELECTRONIC IGNITION BGD36CFNTRE BGD36CFPTR PROPANE MILLIVOLT BGD36CFPTRE PROPANE ELECTRONIC IGNITION W415-1345 / C / 02.14.17...
  • Page 7 VENT BOTTOM / EVENT INFERIEUR T BOTTOM / EVENT INFERIEUR BOTTOM / EVENT INFERIEUR 1" L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. MANTEL / MANTEAU 12" * REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT * MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2".
  • Page 8 3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT (0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 9 When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the following termination kits: wall terminal kit GD-222, GD-222R, or 1/12 to 7/12 pitch roof terminal kit GD-110, 8/12 to 12/12 roof terminal kit GD-111, fl at roof terminal kit GD-112 or periscope kit GD-201 (for wall penetration below grade).
  • Page 10 16" (40.6cm) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) 24" (61cm) MINIMUM MAXIMUM 10" (25.4cm) MINIMUM 42 3/8" (1.08m) MINIMUM PLUS RISE* 34" 34" (86.4cm) (86.4cm) TOP VENT * See "VENTING" section. W415-1345 / C / 02.14.17...
  • Page 11 SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (30.5cm) above grade. The maximum allowable vent length is 10’...
  • Page 12 VENT TERMINAL CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL (0.9m) (4.6m) INSTALLATIONS CANADA U.S.A. 12” (30.5cm) 12” (30.5cm) Clearance above grade, veranda porch, deck or balcony. 12” (30.5cm) Δ 9” (229mm) Clearance to windows or doors that open. 12”...
  • Page 13 VENT APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 14 ELBOW VENT LENGTH VALUES FEET INCHES MILLIMETERS 1° 0.03 12.7 15° 0.45 152.4 30° 11.0 279.4 45° 1.35 16.0 406.4 90°* 32.0 812.8 * The fi rst 90° offset has a zero value and is shown in the formula as - 90° 15.1A TOP EXIT HORIZONTAL TERMINATION ) <...
  • Page 15 ) > (V Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V the required horizontal run H 150 (381) 147 (373.4) REQUIRED VERTI- CAL RISE IN INCHES 100 (254) (CENTIMETERS) V 57 (144.8) 50 (127) 29 (73.7) 20 (6.1)
  • Page 16 REAR EXIT HORIZONTAL TERMINATION ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 40 (12.2) 38.3 (11.7) 30 (9.1) REQUIRED VERTICAL RISE IN 20 (6.1) FEET (METERS) V 10 (3.1)
  • Page 17 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H 12.5 (3.8) 12.25 (3.7) REQUIRED VERTICAL RISE IN 8.3 (2.54) FEET (METERS)V (1.68) 4.2 (1.3) (0.3) 12.5 17.5...
  • Page 18 3.10 TOP OR REAR EXIT VERTICAL TERMINATION ) < (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1) 3 (0.9) (1.5)
  • Page 19 ) > (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL 10 (3.1) RISE IN FEET 3 (0.9) (METERS)V (1.5) (3.1) (4.6) (6.1) (7.6) (9.1) HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS)H The shaded area within the lines represents acceptable...
  • Page 20 4.0 PRE-INSTALLATION PREPARATION For optimum performance, it is recommended that all horizontal runs have a 1" (25mm) rise per foot. DOOR OPERATION Release the top and bottom door latches, located at the right side of the door. REAR EXIT WARNING FAILURE TO CREATE A SEAL TO THE FIREBOX WITH THE EXHAUST COLLAR ASSEMBLY WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE.
  • Page 21 5.0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY. IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE, ENSURE THE REMOTE RECEIVER IS IN THE “OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.
  • Page 22 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 23 USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 24 5.4.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” (51mm) SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. NOTE : Fastening hardware provided with appropriate roof terminal and liner kits. Fasten the roof support to the roof using 6 screws. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 25 5.4.3 APPLIANCE VENT CONNECTION Install the inner exhaust fl ue collar to the appliance. Secure #8 X 1/2” with a minimum of 3 #8 screws. Seal the joint and screw SELF holes using Mill Pac sealant (W573-0007) (not supplied). DRILLING Install the outer fl...
  • Page 26 5.5.3 VERTICAL AIR TERMINAL INSTALLATION NOTE: Before attaching elbows to the collars on the back of the appliance, 1 1/2” (38.1mm) will need to be trimmed off the 4” (101.6mm) collar. REAR VENT APPLICATION: Attach 4” (101.6mm) and 7” (177.8mm) elbows to the appliance. Secure with three screws and seal the joints and screw heads using high temperature INNER PIPE sealant.
  • Page 27 VERTICAL THROUGH EXISTING CHIMNEY WARNING RISK OF FIRE! CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON-COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD RESULT IN A FIRE. This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum fl ex vent system running the full length of a masonry chimney.
  • Page 28 MOBILE HOME INSTALLATION This appliance must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate.
  • Page 29 OPTIONAL WALL SWITCH WARNING DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The recommended maximum lead length depends on wire size: WIRE SIZE MAX.
  • Page 30 Minimum clearance to combustible construction from appliance and vent surfaces: Combustible Framing: 3 1/2" (89mm) from top of stand-offs 1" (25mm) to bottom and sides of the vent pipe* 2" (51mm) to top of the vent pipe* Combustible Finishing: 0" to rear 0"...
  • Page 31 MINIMUM FRAMING DIMENSIONS WARNING FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (35.6cm) WIDE AREA CENTRED ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED. 49"...
  • Page 32 INSIDE 17 1/4" CHASE 43.8cm 40 1/2" 1.03m 6" 41 3/8" 1.05m OUTSIDE 17 1/4" 43.8cm CHASE 40 1/2" 1.03m 12'' (30.5cm) TO COMBUSTIBLE MANTLE IMPORTANT: THIS AREA MUST Encroaching in this area with fi nishing material will interfere REMAIN EXPOSED TO with the opening of the door.
  • Page 33 MINIMUM ENCLOSURE CLEARANCES 6.3.1 REAR VENT ENCLOSURE NON-COMBUSTIBLE COMBUSTIBLE TOP OF COMBUSTIBLE ENCLOSURE SHELF 6 1/2" 0” IF NON- 165mm COMBUSTIBLE FINISHING IS USED SUCH AS 2" BRICK AND STONE 50.8mm 40 1/2" 1.03m 1" 34" 25mm 24 1/2" 86.4cm 62.2cm MINIMUM PLUS RISE**...
  • Page 34 6.3.2 TOP VENT ENCLOSURE NON-COMBUSTIBLE COMBUSTIBLE 2" SHELF 2" COMBUSTIBLE 50.8mm 0” IF NON- 50.8mm MATERIAL COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE 1 1/2" 15" 38.1cm 38mm 1" 25mm MIN NON- 6 1/2" COMBUSTIBLE 165mm MATERIAL STEEL HEADER 49"...
  • Page 35 6.3.3 FINISHED FLOOR INSTALLATION When installing to a fi nished fl oor the appliance riser must create a minimum clearance of 3 3/8" (85.7mm) from the fi nished fl oor to the bottom of the appliance. COMBUSTIBLE STEEL STEEL MATERIAL HEADER HEADER CEMENT BOARD...
  • Page 36 NON-COMBUSTIBLE FACING MATERIAL NON-COMBUSTIBLE FINISH FACING MATERIAL FRONT OF FINISH MATERIAL MATERIAL APPLIANCE 2" (51mm) 4" (102mm) TOP OF 4" (102mm) 6" (152mm) APPLIANCE 2" (51mm) 0" (0mm) 0" (0mm) NON-COMBUSTIBLE 2" (51mm) FACING MATERIAL 4" (102mm) 6" (152mm) 4" (102mm) 2"...
  • Page 37 ALCOVE FRAMING RECESS OR ALCOVE AREA ENCLOSURE AREA APPLIANCE NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are maintained. Non-combustible material can be used, provided the minimum clearances to combustible materials are applied The minimum enclosure volume must be increased by no less than the volume of the recess.
  • Page 38 MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 39 CLEAN FACE TRIM KIT INSTALLATION From the rear side of the clean face front, insert the weld studs on the top window plate assembly upward through the holes on the underside of the top section of the clean face front. Using a socket wrench, secure using the nuts and washers provided.
  • Page 40 76.1A PHAZER logs and glowing embers exclusive to Napoleon, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour pigments burn in during the heat activated curing process.
  • Page 41 CHARCOAL EMBERS Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used. NOTE: Charcoal embers are not to be placed on the burner. 32.1 GLOWING EMBERS Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of...
  • Page 42 OPERATION (ELECTRONIC) WARNING Ensure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the appliance will emit an odor for a few hours, in larger units, this might take longer depending on the size. This is a normal temporary condition caused by the "burn-in" of paints and lubricants used in the manufacturing process and will not occur again.
  • Page 43 10.0 OPERATION (MILLIVOLT) WARNING Ensure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the appliance will emit an odor for a few hours. This is a normal temporary condition caused by the "burn-in" of paints and lubricants used in the manufacturing process and will not occur again.
  • Page 44 11.0 ADJUSTMENT 11.1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise PILOT direction to reduce the gas fl ow. BURNER THERMOPILE Inlet pressure can be checked by turning screw (A) THERMOCOUPLE counter-clockwise until loosened and then placing pressure gauge tubing over the test point.
  • Page 45 11.3 FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ame 3/8” - 1/2” appears abnormal call a service person. (9.5mm - 12.7mm) FLAME MUST ENVELOP UPPER 3/8"...
  • Page 46 12.1 ANNUAL MAINTENANCE WARNING THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE. NEVER VACUUM HOT EMBERS. DO NOT PAINT THE PILOT ASSEMBLY. • This appliance will require maintenance which should be planned on an annual basis. •...
  • Page 47 12.2 DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 48 13.0 REPLACEMENTS WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. ** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
  • Page 49 W415-1345 / C / 02.14.17...
  • Page 50 W415-1345 / C / 02.14.17...
  • Page 51 W415-1345 / C / 02.14.17...
  • Page 52 W415-1345 / C / 02.14.17...
  • Page 53 15.0 TROUBLESHOOTING ELECTRONIC WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 54 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. PILOT Check if the push button igniter needs tightening. BURNER Replace the wire if the wire insulation is broken or frayed.
  • Page 55 16.0 TROUBLESHOOTING MILLIVOLT WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 56 SYMPTOM PROBLEM TEST SOLUTION Continues to spark Short or loose Verify all connections. Verify the connections from the and pilot lights, but connection in sensor rod. pilot assembly are tight; also verify these connections are main burner will not not grounding out to any metal. light.
  • Page 57 All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge.
  • Page 58 napoleonproducts.com...
  • Page 59 à risque. ÉCRAN DE PROTECTION Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-720-9081 • www.napoleonfoyers.com • hearth@napoleonproducts.com 10,00$ 1.28F...
  • Page 60 TABLE DES MATIÈRES VUE D'ENSEMBLE DE L'INSTALLATION INTRODUCTION DIMENSIONS INSTRUCTIONS GÉNÉRALES INFORMATIONS GÉNÉRALES INFORMATION À PROPOS DE LA PLAQUE D’HOMOLOGATION ÉVACUATION LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS INSTALLATIONS TYPIQUES D'ÉVENTS INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1 ENSEMBLE PÉRISCOPIQUE 3.3.2 INSTALLATION EN COIN EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON CHARTE D'APPLICATION DES ÉVACUATIONS LÉGENDE...
  • Page 61 1.0 VUE D'ENSEMBLE DE L'INSTALLATION Voir la section « DÉGAGEMENTS MINIMAUX DE L’ENCEINTE » pour les cloisons sèches (ou autre matériau combustible). Voir la section « DÉGAGEMENTS Voir les sections MINIMAUX DE LA « ÉVACUATION » et TABLETTE ». « INSTALLATION ». Voir la section «...
  • Page 62 2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET SONT INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 63 DIMENSIONS 5" 127mm 38 1/2" 978mm 7" 34" 27" 686mm 178mm 864mm L’ÉCRAN DE PROTECTION 8" 4" 24 1/4" 203mm 102mm ENTRÉE 616mm DU GAZ 3" 76mm 40" 1016mm 15" 381mm 17" 432mm W415-1345 / C / 02.14.17...
  • Page 64 INSTRUCTIONS GÉNÉRALES AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. PRÉVOYEZ UN ACCÈS SUFFISANT POUR ENTRETENIR ET OPÉRER L’APPAREIL. ASSUREZ-VOUS D'UNE QUANTITÉ SUFFISANTE D’AIR DE VENTILATION. N’OBSTRUEZ JAMAIS L’OUVERTURE DE L’APPAREIL.
  • Page 65 INFORMATIONS GÉNÉRALES POUR VOTRE SATISFACTION, CET APPAREIL A ÉTÉ MIS À L'ESSAI POUR CONFIRMER SON FONCTIONNEMENT ET SA QUALITÉ! RENDEMENTS ET EFFICACITÉS Altitude (PI) 0-4,500 0-4500 Débit max. (BTU/H) 17,000 17,000 Rend. max. (BTU/H) 10,900 10,900 Effi cacité (souf. allumée) A.F.U.E.
  • Page 66 SIDES / COTES VENT TOP / EVENT SUPERIEUR SUPERIEUR RIEUR 2" AFTER SERVICING THE VENT-AIR INTAKE SYSTEM. L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. BACK / ARRIERE VENT BOTTOM / EVENT INFERIEUR EVENT INFERIEUR EVENT INFER 1"...
  • Page 67 3.0 ÉVACUATION AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’ÉVENT ET À L’APPAREIL. SI LE SYSTÈME D’ÉVENT EST FOURNI AVEC DES ESPACEURS, LES COURSES HORIZONTALES ET VERTICALES DU SYSTÈME DOIVENT ÊTRE SUPPORTÉES À TOUS LES 3 PI (0,9m). UTILISEZ DES SUPPORTS OU DES ATTACHES INCOMBUSTIBLES ÉQUIVALENTS AFIN DE MAINTENIR LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES.
  • Page 68 LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent ou Metal-Fab. Les minimums et maximums des longueurs d’évent, pour les installations verticales et horizontales, et les emplacements des terminaisons pour les deux systèmes sont précisés dans ce manuel et doivent être respectés.
  • Page 69 INSTALLATIONS TYPIQUES D'ÉVENTS 16" (40.6cm) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) MINIMUM 20" (50.8cm) MAXIMUM 24 1/4" (61.6cm) 24 1/4" MINIMUM PLUS LA (61.6cm) PENTE* * See "VENTING" section. REAR VENT W415-1345 / C / 02.14.17...
  • Page 70 16" (40.6cm) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) 24" (61cm) MINIMUM MAXIMUM 10" (25.4cm) MINIMUM 42 3/8" (1.08m) MINIMUM PLUS LA PENTE* 34" 34" (86.4cm) (86.4cm) TOP VENT * Voir la section « ÉVACUATION » W415-1345 / C / 02.14.17...
  • Page 71 INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1 ENSEMBLE PÉRISCOPIQUE Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces (30,5cm) au-dessus du niveau du sol.
  • Page 72 EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON ††* APPLICATIONS POUR BALCON COUVERT INSTALLATION = 3 pieds = 2 x RÉELLE (0,9m) (4,6m) CANADA É.-U. 12” (30,5cm) 12” (30,5cm) Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon. 12”...
  • Page 73 CHARTE D'APPLICATION DES ÉVACUATIONS ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale La course verticale La course verticale est plus grande ou est plus grande ou est plus petite est plus petite égale à la course égale à...
  • Page 74 LÉGENDE Les symboles suivants sont utilisés dans le calcul et les exemples d’évacuation : > - plus grand que > - plus grand ou égal à < - plus petit que < - plus petit ou égal à - total de la longueur des courses horizontales (Hr) et des déviations (Ho) en pieds - longueur des courses horizontales combinées en pieds - facteur de la valeur d’une déviation : 0,03 (du total des degrés de déviation - 90°*) en pieds - longueur des courses verticales combinées en pieds...
  • Page 75 ÉVACUATION SUR LE DESSUS TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple (un coude de 90° Consultez le graphique pour déterminer la course verticale seulement). nécessaire V par rapport à la course horizontale requise H 40 (12,2) 39 (11,9) 30 (9,1) COURSE VERTICALE REQUISE EN...
  • Page 76 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H (un coude de 90° seulement) 150 (3810) 147 (3733,8) COURSE VERTICALE 100 (2540) REQUISE EN POUCES (MILLMÈTRES)V 57 (1447,8) 50 (1270)
  • Page 77 ÉVACUATION À L'ARRIÈRE TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire (deux coudes de 90° seulement) par rapport à la course horizontale requise H 40 (12,2) 38,3 (11,7) COURSE 30 (9,1) VERTICALE REQUISE EN PIEDS...
  • Page 78 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (deux coudes de 90° seulement) nécessaire V par rapport à la course horizontale requise H 150(3810) 147 (3733,8) COURSE VERTICALE 100 (2540) REQUISE EN PIEDS (MÈTRES) V (1676,4) 50 (1270) 12 (304,8)
  • Page 79 3.10 ÉVACUATION SUR LE DESSUS OU À L'ARRIÈRE TERMINAISON VERTICALE ) < (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE 20 (6,1) REQUISE EN PIEDS...
  • Page 80 ) > (V Configurations d'évacuation simples. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6) (6,1)
  • Page 81 Exemple : = 1,5 PI (0,5m) = 5 PI (1,5m) = 1,5PI (0,5m) + 5PI (1,5m) = 6,5 PI (2m) = 1 PI (0,3m) = 1 PI (0,3m) = 10,75 PI (3,3m) = 1PI (0,3m) + 1PI (0,3m) + 10,75PI (3,3m) = 12,75PI (3,9m) 90°...
  • Page 82 5.0 INSTALLATION AVERTISSEMENT AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE, ASSUREZ-VOUS DE RETIRER TOUTE COMPOSANTE NON FIXÉE À L’INTÉRIEUR DE LA CHAMBRE DE COMBUSTION. SI VOTRE APPAREIL COMPREND UN SYSTÈME DE TÉLÉCOMMANDE, ASSUREZ-VOUS QUE LE RÉCEPTEUR EST À LA POSITION « OFF » AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE.
  • Page 83 INSTALLATION HORIZONTALE AVERTISSEMENT L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. LA TERMINAISON NE DOIT PAS ÊTRE ENCHÂSSÉE DANS LE MUR OU LE REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. PROTECTEUR Cette confi...
  • Page 84 INSTALLATION VERTICALE Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « Accessoires » pour commander l’ensemble spécifi que dont vous avez besoin. Une fois que vous aurez déterminé...
  • Page 85 5.4.1 INSTALLATION DE LA TERMINAISON HORIZONTALE Étirez la gaine fl exible intérieure à la longueur requise en tenant compte de la longueur CALFEUTRAGE GAINE FLEXIBLE additionnelle nécessaire pour la surface du mur EXTÉRIEURE CALFEUTRAGE fi ni. Appliquez un généreux joint de scellant à haute température Mill Pac (W573-0007) (non fourni).
  • Page 86 5.4.2 INSTALLATION DE LA TERMINAISON VERTICALE AVERTISSEMENT CONSERVEZ UN ESPACE MINIMAL DE 2" (51mm) ENTRE LA BASE DE LA PRISE D’AIR ET LE COLLET DE SOLIN. NOTE : Matériel de fi xation fourni avec les ensembles de terminal pour toit et raccord appropriées. Fixez le support de toit au toit à...
  • Page 87 5.5.2 RACCORDEMENT DES ÉVENTS À L'APPAREIL Raccordez la collet d’évacuation à l’appareil. Fixez avec un minimum de trois vis #8. Scellez le joint et les têtes de vis AUTOPER- avec le scellant à haute température Mill-Pac W573-0007 CEUSES (non fourni). #8 X 1/2”...
  • Page 88 5.5.3 INSTALLATION DE LA TERMINAISON HORIZONTALE PROLONGÉE AJUSTABLE Une installation en coin de 45° peut avoir une élévation de 0” (0mm) entre TERMINAISON MANCHON le collet d’air de combustion de l’appareil et la terminaison. Dans ce cas, TÉLESCOPIQUE les longueurs de l’évent ne doivent pas dépasser 24" (61cm). Pour des longueurs d’évent horizontales plus grandes, une élévation verticale BAGUE D’ACCOUPLEMENT...
  • Page 89 5.5.4 INSTALLATION DE LA TERMINAISON VERTICALE NOTE: Before attaching elbows to the collars on the back of the appliance, 1 1/2” (38.1mm) will need to be trimmed off the 4” (101.6mm) collar. REAR VENT APPLICATION: Attach 4” (101.6mm) and 7” (177.8mm) elbows to the appliance. Secure with three screws and seal the joints and screw heads using high temperature INNER PIPE sealant.
  • Page 90 TERMINAISON VERTICALE À TRAVERS UNE CHEMINÉE EXISTANTE AVERTISSEMENT RISQUE D'INCENDIE! LES CONFIGURATIONS D'ÉVACUATION COAXIALES À COLINÉAIRES NE DOIVENT ÊTRE UTILISÉES QUE DANS UNE CHEMINÉE OU UNE ENCEINTE DE NATURE INCOMBUSTIBLE. UNE INSTALLATION DANS UNE ENCEINTE COMBUSTIBLE PEUT CAUSER UN INCENDIE. Cet appareil est conçu pour être raccordé...
  • Page 91 INSTALLATION DANS UNE MAISON MOBILE Cet appareil doit être effectuée en respectant les directives du fabricant et le Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, aux États-Unis, ou les normes actuelles pour les maisons mobiles, CAN/CSA Z240 SÉRIE MH, au Canada. Cet appareil ne doit être utilisé qu’avec le type de gaz indiqué sur la plaque d’homologation.
  • Page 92 BRANCHEMENT DU GAZ AVERTISSEMENT RISQUE D'INCENDIE, D'EXPLOSION OU D'ASPHYXIE. ASSUREZ-VOUS QU'IL N'Y AIT AUCUNE SOURCE D'ALLUMAGE COMME DES ÉTINCELLES OU UNE FLAMME NUE. SOUTENEZ LE CONTRÔLE DU GAZ LORSQUE VOUS ATTACHEZ LE TUYAU POUR ÉVITER DE PLIER LA CONDUITE DE GAZ. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 93 6.0 OSSATURE AVERTISSEMENT RISQUE D’INCENDIE! AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CONTACT AVEC L’EXTÉRIEUR DU CAISSON, IL EST CONSEILLÉ D’INSTALLER L’APPAREIL CONTRE DES MURS FINIS (C.-À-D. PANNEAU DE GYPSE) COMME TOUT AUTRE MUR DE LA MAISON. CECI ASSURERA QUE LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES EST MAINTENU.
  • Page 94 Il est préférable de construire l'ossature après que l'appareil est en place et que le système d'évacuation est in- stallé. Construisez conformément aux exigences des codes du bâtiment locaux. Il n'est pas nécessaire d'installer une base de protection avec ce type d'appareil. Lorsque vous mettez l'appareil en place, surélevez-le de façon à...
  • Page 95 6.1.1 DIMENSIONS MINIMALES DE L’OSSATURE AVERTISSEMENT POUR DES APPLICATIONS AVEC ÉVACUATION SUR LE DESSUS : NE CONSTUISEZ RIEN DANS CET ESPACE DE 14 PO (356MM) DE LARGEUR, CENTRÉ LE LONG DE L'AVANT DE L'APPAREIL. CET ESPACE DOIT RESTÉ LIBRE AFIN D'OFFRIR UN DÉGAGEMENT ADÉQUAT POUR L'ÉVACUATION. AUCUN MATÉRIAU COMBUSTIBLE N'EST PERMIS.
  • Page 96 ENCEINTE 17 1/4" INTÉRIEURE 43.8cm 40 1/2" 102.8cm 41 3/8" 6" 105cm 15.2cm ENCEINTE 17 1/4" EXTÉRIEURE 43.8cm 40 1/2" 102.8cm IMPORTANT : 12'' (30,5cm) À LA TABLETTE Pour permettre l'ouverture de la porte, les matériaux de COMBUSTIBLE fi nition ne doivent pas déborder dans cet espace. CETTE SECTION DOIT DEMEURER DÉGAGÉE POUR PERMETTRE...
  • Page 97 MINIMUM ENCLOSURE CLEARANCES 6.2.1 REAR VENT ENCLOSURE NON-COMBUSTIBLE COMBUSTIBLE TOP OF COMBUSTIBLE ENCLOSURE SHELF 6 1/2" 0” IF NON- 165mm COMBUSTIBLE FINISHING IS USED SUCH AS 2" BRICK AND STONE 50.8mm 40 1/2" 1.03m 1" 34" 25mm 24 1/2" 86.4cm 62.2cm MINIMUM PLUS RISE**...
  • Page 98 6.2.2 ENCEINTE POUR UNE ÉVACUATION SUR LE DESSUS 2" MATÉRIAU TABLETTE 2" 5.1cm COMBUSTIBLE 0” SI UN MATÉRIAU DE 5.1cm FINITION INCOMBUSTIBLE EST UTILISÉ TEL QUE DE LA 1 1/2" BRIQUE ET DE LA PIERRE 15" 38mm 38.1cm 1" 6 1/2" 16.5cm 25mm MIN.
  • Page 99 6.2.3 INSTALLATION DU PLANCHER FINI Lorsque la base d'élévation est installée sur un plancher fi ni, un dégagement minimal de 3 3/8" (86mm) est nécessaire entre le plancher fi ni et le bas de l'appareil. MATÉRIAU LINTEAU EN LINTEAU COMBUSTIBLE ACIER EN ACIER MATÉRIAU...
  • Page 100 MATÉRIAU DE FINITION INCOMBUSTIBLE INCOMBUSTIBLE LA FACE DE L’APPAREIL LA FACE DE 4" (102mm) 2" (51mm) L’APPAREIL 2" (51mm) 4" (102mm) 0" (0mm) 6" (152mm) 6" (152mm) 0" (0mm) 4" (102mm) INCOMBUSTIBLE 2" (51mm) 2" (51mm) 4" (102mm) AVERTISSEMENT: Les matériaux de finition incombustibles ne doivent pas dépasser de la sommet, du fond ou des côtés de l’appareil, comme illutsrée (pour une projection maximale de 6”...
  • Page 101 INSTALLATION TÉLÉCOMMANDE BASE DU FOYER BOÎTE DE DÉRIVATION PLACER LE TÉLÉCOMMANDE SUR CETTE ÉTIQUETTE Positionner le télécommande aux compartiment du soupape près du boite de dérivation électrique. Assurez-vous que le télécommande est en haut de l’étiquette de placement, si équipé. 35.25 DÉGAGEMENTS MINIMAUX DE LA TABLETTE AVERTISSEMENT...
  • Page 102 7.0 FINITION OUVERTURE ET FERMETURE DE LA PORTE AVERTISSEMENT LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. SI ÉQUIPÉ AVEC LES LOQUETS DE PORTE QUI FONT PARTIE D'UN DISPOSITIF DE SÉCURITÉ ET DOIVENT ÊTRE ADÉQUATEMENT VERROUILLÉS.
  • Page 103 DISPOSITION DES BÛCHES AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 104 Alignez le trou carré de la bûche transversale Alignez le trou rectangulaire de la bûche droite avec la tige carrée située du côté droit transversale gauche avec la tige rectangulaire de la bûche et installez tel qu'illustré. située du côté gauche de la bûche et installez tel qu'illustré.
  • Page 105 ENSEMBLE DE ROCHES OPTIONNEL (L’ENSEMBLE ADAPTATEUR RAK-ROCK DOIT ÊTRE UTILISÉ AVEC CET ENSEMBLE.) AVERTISSEMENT NE PAS UTILISER DE VRAIES ROCHES DANS CET APPAREIL. LA CHALEUR LES FERA ÉCLATER. SUPPORT À BÛCHES SUPPORT DE ROCHES Enlevez tous les composants décoratifs et les Mettez les deux amas de roches en place, en bûches.
  • Page 106 8.0 INSTALLATION DE LA SOUFFLERIE OPTIONNELLE AVERTISSEMENT RISQUE D’INCENDIE ET DE CHOC ÉLECTRIQUE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. N’UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES PIÈCES DE RECHANGE APPROUVÉS PAR WOLF STEEL POUR CET APPAREIL.
  • Page 107 INTERRUPTEUR THERMIQUE Fixez l’interrupteur à vitesse variable à l’aide de l’écrou fourni à cet effet. Branchez le cordon d’alimentation dans le réceptacle. Le harnais de RÉCEPTACLE / fils fourni dans cet ensemble est un harnais BOÎTE DE DÉRIVATION universel. Lors de son installation, assurez-vous BOUTON DE que tout excès de fil est confiné, l'empêchant CONTRÔLE...
  • Page 108 9.0 FONCTIONNEMENT (ÉLECTRONIQUE) AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 109 10.0 FONCTIONNEMENT (MILLIVOLT) AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POUR- RAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 110 11.0 RÉGLAGES 11.1 RÉGLAGE DE LA VEILLEUSE Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. VEILLEUSE Tournez vers la droite pour réduire l’apport de gaz. THERMOPILE Pour vérifi er la pression d’arrivée, tournez la vis (A) vers la THERMOCOUPLE gauche jusqu’à...
  • Page 111 11.3 CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. 3/8” - 1/2” Comparez-les à ces illustrations. Si des fl ammes paraissent (9,5mm - 12,7mm) anormales, contactez un technicien de service. LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE...
  • Page 112 12.1 ENTRETIEN ANNUEL AVERTISSEMENT LE CAISSON DEVIENT TRÈS CHAUD LORS DU FONCTIONNEMENT. LAISSEZ L’APPAREIL SE REFROIDIR COMPLÈTEMENT OU PORTEZ DES GANTS ANTICHALEUR AVANT D’EFFECTUER L’ENTRETIEN. NE JAMAIS ASPIRER DES BRAISES QUI SONT CHAUDES. NE PEINTUREZ PAS L’ASSEMBLAGE DE LA VEILLEUSE. •...
  • Page 113 12.2 REMPLACEMENT DE LA VITRE DE PORTE AVERTISSEMENT N’UTILISEZ PAS DE MATÉRIAUX DE SUBSTITUTION. LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. UTILISEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES DÉBRIS DE VERRE OU DES COMPOSANTS ENDOMMAGÉS.
  • Page 114 13.0 RECHANGES AVERTISSEMENT OMETTRE DE POSITIONNER LES PIÈCES CONFORMÉMENT À CE MANUEL OU D’UTILISER UNIQUEMENT DES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. ** CECI EST UN THERMOCOUPLE À ACTION RAPIDE QUI CONSTITUE UN COMPOSANT ESSENTIEL DE SÉCURITÉ.
  • Page 115 W415-1345 / C / 02.14.17...
  • Page 116 W415-1345 / C / 02.14.17...
  • Page 117 W415-1345 / C / 02.14.17...
  • Page 118 W415-1345 / C / 02.14.17...
  • Page 119 18.0 GUIDE DE DÉPANNAGE MAINTENANCE MAINTENANCE AVERTISSEMENT MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 120 SYMPTÔME PROBLÉME SOLUTIONS La veilleuse ne Aucune étincelle au brûleur de Vérifi ez si la veilleuse peut être allumée avec une allumette. s’allume pas. la veilleuse. Vérifi ez si le fi l est raccordé au bouton-poussoir d’ignition. Vérifi ez si le bouton-poussoir d’ignition doit être resserré. VEILLEUSE Remplacez le fi...
  • Page 121 19.0 GARANTIE Les produits NAPOLÉON sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits NAPOLÉON sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 122 20.0 NOTES 44.1 W415-1345 / C / 02.14.17...
  • Page 123 44.1 W415-1345 / C / 02.14.17...
  • Page 124 napoleonproducts.com...