6.4
CLEAN FACE SURROUND FRAMING AND FINISHING EXCLUDING GD36M
WAVE
S36WN (BROWN)
S36WP (PEWTER)
Installation requires a minimum of 6 1/2" (165mm) non-combustible facing material at the top of the appliance.
Refer to illustrations above (depending on your installation) to ensure your appliance has been installed with
the proper requirements for this kit.
Whether installing to a fi nished fl oor or a hearth, a 3/8" (9.5mm) clearance must be maintained at the bottom of
the clean face surround kit. To obtain this clearance an appliance riser is required.
6.4.1 FINISHED FLOOR INSTALLATION
When installing to a fi nished fl oor the appliance riser must create a minimum clearance of 3 3/8" (86mm) from
the fi nished fl oor to the bottom of the appliance.
STAND OFF
CLEAN FACE SURROUND KIT
CLEANFACE SURROUND
FINISHED FLOOR
STEEL
HEADER
(SUPPLIED)
3 3/8"
3 3/8"
85mm
85mm
CLEARANCE
CONVEX
S36CVN (BROWN)
S36CVP (PEWTER)
COMBUSTIBLE
MATERIAL
CEMENT BOARD
PANEL (SUPPLIED)
6 1/2" 165mm MIN
37 3/8"
949mm
CLEARANCE
SURROUND KIT
FIREPLACE
RISER
CONCAVE
S36CCN (BROWN)
S36CCP (PEWTER)
STEEL
HEADER
(SUPPLIED)
STAND OFF
FIREPLACE
RISER
3 3/8"
3 3/8"
FINISHED FLOOR
85mm
85mm
CLEARANCE
W415-1132 / C / 08.20.13
37
EN