(1) At the following conditions: condenser inlet air temperature 35°C; cooled water temperature 7°C; temperature differential at the evaporator 5 K;
fouling factor equal to 0.35x10-4 m2 K/W.
(2) At the following conditions: evaporator inlet air temperature 7°C B.S., 6°C B.U.; hot water temperature 45°C; condenser temperature differential 5 K;
fouling factor equal to 0.35x10-4 m2 K/W.
(3) At the following conditions: condenser inlet air temperature 35°C; cooled water temperature 18°C; temperature differential at the evaporator 5 K;
fouling factor equal to 0.35x10-4 m2 K/W.
(4) At the following conditions: evaporator inlet air temperature 7°C B.S., 6°C B.U.; hot water temperature 35°C; condenser temperature differential 5 K;
fouling factor equal to 0.35x10-4 m2 K/W.
(5) Sound pressure level in dB(A) referring to a 5 m distance from the unit, in free field and directionality factor equal to Q=2 (P0/PI0/ASP0/ASPI0
set up)
(6) Sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards.
(7) The value of the inrush current is valid upon activation of the second compressor (fixed speed scroll) (only for 262)
(±) Recovery unit heating capacity. Conditions referring to the unit operating with chilled water temperature 7°C, differential temperature due to
evaporation of 5 K, hot water temperature produced equivalent to 40/40°C (RC100) 45/45°C (DS). NB. With heat pumps operating in winter mode with
DC active, the heating capacity available is decreased from the portion supplied to the desuperheater
(■) Current absorbed by compressors and fans
(●) Power absorbed by compressors and fans
(*) The data according to EN 14511 refer to the P0/PI0/ASP0/ASPI0 set up. Refer to the "UpToDate" software for information relating to the P1/ASP1
set up
(§) In average climatic conditions according to Regulation N° 811/2013
(O) With the SIL accessory, the value decreases by 1dB(A)
SI Inverter regulated scroll (variable speed)
SF Fixed speed scroll
The refrigerant charge values are indicative. Refer to the serial number plate
IOM_EWMIM-EWMIMH_120a262_207984_200601_ES-EN-FR-DE-IT