Alarm
Alarm priority
Source
level
ECG
SpO
2
High
Respiration
Temperature
NIBP
ECG
Medium
ECG
Low
Alarm priority
Alarm
level
source
High
System
ECG/SpO
Medium
IBP
NIBP
Low
TEMP
CSM
Related to 3 levels alarm sources, medical and nursing staff should have different response to deal with potential
dangerous, the detailed demands as follows:
1. High priority alarm: medical and nursing staff should response immediately.
2. Medium priority alarm: medical and nursing staff should response quickly.
3. Low priority alarm: medical and nursing staff should response as soon as possible.
NOTE: Some models may have only Medium and Low alarm priority because of the different configuration.

6.3 Alarm Indicators

When an alarm occurs, the monitor will indicate it to the user through visual or audible alarm indications.
Operator's Manual for Patient Monitor
Physiological alarm
Alarm Event
Unable to detect HR, ECG Arrest, ECG Brady, ECG Tachy, VE RUN,SVE RUN, HR is too
high, HR is too low, S-T is too high, S-T is too low, VE Run, ECG VPCEST
Unable to detect SpO
Apnea, RR too high, RR too low
Temp1 too high, Temp1 too low, Temp2 too high, Temp2 too low, TD too high
NIBP SYS too high, NIBP SYS too low, NIBP DIA too high, NIBP DIA too low, NIBP MAP too
high, NIBP MAP too low, PR too high, PR too low
VE RonT, SVE RonT, S-T1 too high, S-T1 too low, S-T2 too high, S-T2 too low, S-T3 too
high, S-T3 too low, S-T4 too high, S-T4 too low, S-T5 too high, S-T5 too low, S-T6 too
high, S-T6 too low, S-T7 too high, S-T7 too low
Miss Beat, VE Early, SVE Early, VE Couplet, SVE Couplet, VE Short Run, SVE Short Run,
SVE Run, VE Insert, SVE Insert, VE Bigeminy, SVE Bigeminy, VE Trigeminy, SVE Trigeminy,
Multiform Beat
Alarm Events
Low battery, SpO
2
Lead(s) off, SpO
Probe off, SpO
2
2
range
IBP1 Probe off, IBP2 Probe off, IBP3 Probe off, IBP4 Probe off
Self-test failed, System error, Over time, Signal weak, Cuff error, Air leakage, Pressure
error, Out of range, Too much motion, Over pressure, Signal saturation, Detected air
leakage, BP exceeds measuring range,
Temperature self-detect failed, TEMP1/TEMP2 exceed(s) measuring range
Electrodes off
, SpO
too high, SpO
2
2
2
Technical alarm
modular malfunction, Unknown error
value exceeds measuring range, HR exceeds measuring
2
43
too low, PR too high, PR too low