INSTALLATION
Table
Type of hob
Appliance width x depth
Installation height from top of worktop
Cut out dimensions width x depth
Distance from saw line to rear wall
Distance from appliance to side wall
Space to be left free around the appliance
A hob generates heat. Leave a sufficient distance between the appliance
and non heat-resistant materials. Take care also with materials that may
discolour (such as stainless steel).
min. 650 mm
min. 450 mm
min. 100 mm
The gas hob may only be built in next to one vertical wall.
please note
The bottom of the hob becomes hot. Do not place combustible items in
a drawer if the drawer is fitted directly below the hob.
182
building in
IG9071M
904 x 522 mm
48 mm
860 x 490 mm
50 mm minimum
100 mm minimum
min.s 900
side-panel
min. 100 mm
INSTALLATION
Ventilation
The electronics in the appliance require cooling. The ventilation
openings are located on the underside of the appliance. It must be
possible for cool air to be drawn in through these openings. The
appliance is fitted with outlet openings at the front and bottom. The
kitchen unit will require a few modifications to allow optimum cooling
of the hob.
Above drawer or fixed panel
Saw out the ventilation openings (min. 100 cm
and rear of cupboard.
B
A
Do not allow the ventilation openings on the underside of the appliance
to be blocked by a drawer. Where there is a drawer, a gap of at least
560 x 6 mm should be made at the front. The distance between drawer A
and the hob should be a minimum of 10 mm.
min.
10 mm
150
building in
). Ventilation is via plinth
2
min.
560 x 6 mm
A
A
183