FAULTS WOK BURNER
Fault
Cause
There is a smell of gas in the
– The burner is switched on but
vicinity of the appliance.
not lit (only applies to
IG9071MX).
– The coupling on a bottled gas
unit has come undone.
A burner does not ignite.
– Plug not in socket.
– Fuse defective/fuse in meter
cabinet switched off.
– Sparkplug dirty/damp.
– Burner parts not correctly
installed.
– Burner parts dirty/damp.
– Main gas tap closed.
– Fault in the gas network.
– Gas bottle or tank is empty.
– Wrong type of gas used (where
bottled gas is used).
– Control knob not kept pressed
in long enough or far enough.
The burner does not burn evenly.
– Burner parts incorrectly installed.
– Burner parts dirty or damp.
– Wrong type of gas used (where
bottled gas is used).
The burner goes out after igniting.
– Control knob not kept pressed
in long enough (only applies to
IG9071MX).
170
table
Solution
– Close the tap and wait for a few
minutes before relighting.
– Tighten the coupling.
– Push the plug into the socket.
– Fit a new fuse or switch the
automatic fuse back on.
– Clean and dry the sparkplug.
– Assemble the burner parts using
the centring ridges.
– Clean and dry the burner parts,
making sure that the outflow
holes are open.
– Open the main gas tap.
– Check with your gas supplier.
– Connect a new gas bottle or
have the tank filled.
– Check that the gas used is
suitable for the appliance.
– Keep the control knob pressed in
far enough between full and low.
– Assemble the burner parts using
the centring ridges.
– Clean and dry the burner parts,
making sure that the outflow
holes are open.
– Check that the gas used is
suitable for the appliance.
– Keep the control knob pressed in
for at least 5 seconds.
FAULTS
In case of faults phone the service department. See the guarantee
certificate or consult the internet site www.hps.nl.
If you notice a crack on the cooking surface (no matter how little),
switch off the appliance immediately. Remove the plug from the socket
or set the switch of the power supply cable (in the case of a fixed
connection) to zero or turn off the fuse switch(es) in the meter cupboard.
Phone the service department.
This appliance should only be connected up by a registered installer!
The electrical connection must comply with national and local
regulations.
Damage caused by incorrect connection, incorrect use or incorrect
building in is not covered by the guarantee.
general