Dipswitch For Time Mode Settings; Stripping The Cable - Speck pumpen BADU Jet Wave Traduction Des Instructions D'utilisation D'origine

Wg23.70.060-p
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 118
Installation
the lighting circuit, this segment can light up briefly due to the
inrush current in the LED lighting module!
*FV* lights up if the voltage in the microprocessor overloads.
Green and orange LEDs on the circuit board
See "Fig. 23" on page 38.
*V* green LED lights up: Power supply present in the circuit board
[Volt].
*M* orange LED lights up: Motor protection has triggered (over
current).
Check the motor protection settings.
Circuit board fuse
See "Fig. 23" on page 38.
*Si* Replaceable fuse: 3.15 A T
The fuse only needs replacing if the green LED [V] is not lit up.
5.5.3

Dipswitch for time mode settings

LED light duration
120 min
180 min
manual
Fig. 25
5.5.4

Stripping the cable

The cable for the power supply should be stripped to a length
of 15 – 17 cm.
40 EN
60 min
ON
1
Pump run time
ON
2
7
8
30 min
15 min
45 min
manual
WG27.50.111-2-P
01|2018