5.5
Supplements for the control boxes with circuit
board
5.5.1
Benefits
•
Pump/LED turns off after a certain amount of time (time
mode).
•
Error recognition due to circuit board display.
•
Clear recognition when the motor protection is triggered.
•
Safety benefits.
•
Overloading the transformer is impossible.
5.5.2
Segment display, green and orange LED, fuse
Fig. 24
*RUN* flashes when the microprocessor is working.
*S1* lights up when one of the pump's buttons is pressed.
*P* lights up, the pump should now work and the pump's
protection should be on.
*P* flashes, the pump should be turned on in time mode and the
pump's protection should be on.
*S2* lights up when the LED light button is pressed.
*L* lights up, the LED light should now be on.
*L* flashes, the LED light should now be on in time mode.
Error message
*FL* lights up if there is a short circuit in the cable to the LED
floodlight.
*FL* flashes if there is a disruption in the cable to the LED
floodlight.
Note: The error message *FL* only occurs if the condition "LED
light turned on" is met. Normally, without there being an error in
01|2018
FV
S1
P
FL
S2
L
RUN
WG27.50.110-P