Check The Pump After The Overload Switch Has Tripped; Spare Parts Lists - Speck pumpen BADU Jet Wave Traduction Des Instructions D'utilisation D'origine

Wg23.70.060-p
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 118
Faults
7.1.1

Check the pump after the overload switch has tripped

If the motor has been switched off by the built-in or external
overload switch, carry out the following steps:
1.
Disconnect the system from the power supply.
2.
Turn the motor shaft on the fan side using a screwdriver and
check whether it turns easily.
If the motor shaft is difficult to turn:
1.
Remove the screwdriver.
2.
Notify Customer Services or your swimming pool builder and
have the pump tested.
If the motor shaft is easy to turn:
1.
Remove the screwdriver.
2.
Open the valves completely.
3.
Reconnect to the power supply.
NOTICE
If the pump seizes and is repeatedly switched on, the motor can
be damaged.
Ensure that the pump/unit is only switched on once.
4.
Wait until the built-in overload switch automatically switches
the motor on after it has cooled down.
– or –
Reset the motor overload switch.
5.
Have an electrician test the power supply, fuses and power
consumption.
6.
If the built-in or external overload switch switches the motor
off again, notify Customer Services.
7.1.2

Spare parts lists

Spare parts lists for each pump can be found on the website
www.speck-pumps.com.
48 EN