Télécharger Imprimer la page

Cameras; Environment; Certifications - Videotec MAXIMUS MVX Manuel D'instructions

Masquer les pouces Voir aussi pour MAXIMUS MVX:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82

16.1.9 Cameras

Power consumption (assembly, camera and lens)
• Without video encoder IP: 8W
• With video encoder IP: 6W
Minimum distance between camera and housing's
window: 4mm (0.16in)
Cameras dimensions/Lenses that can be installed
(WxHxL)
• Without video encoder: 70x65x140mm
(2,6x2,5x5,5in)
• With video encoder: 70mmx65mmx120mm

16.1.10 Environment

For installation indoors and outdoors
Operating temperature:
• Cold start from -40°C (-40°F) up to +65°C (149°F)
• Running from -50°C (-58°F) up to +65°C (149°F)
Relative humidity: from 10% up to 95% (no
condensation)
34

16.1.11 Certifications

ATEX (EN 60079-0: 2012, EN 60079-1: 2014, EN 60079-
31: 2014)
b b II 2 G Ex db IIC T5 Gb
b b II 2 D Ex tb IIIC T100°C Db IP66/IP68
-60°C ≤ Ta ≤ +65°C
b b II 2 G Ex db IIC T5 Gb
b b II 2 D Ex tb IIIC T100°C Db IP66/IP68
-50°C ≤ Ta ≤ +65°C
b b II 2 G Ex db IIC T6 Gb
b b II 2 D Ex tb IIIC T85°C Db IP66/IP68
-60°C ≤ Ta ≤ +55°C
b b II 2 G Ex db IIC T6 Gb
b b II 2 D Ex tb IIIC T85°C Db IP66/IP68
-50°C ≤ Ta ≤ +55°C
IECEx (IEC 60079-0: 2011 Ed.6, IEC 60079-1: 2014-06
Ed.7, IEC 60079-31: 2013 Ed.2)
Ex db IIC T5 Gb
Ex tb IIIC T100°C Db IP66/IP68
-60°C ≤ Ta ≤ +65°C
Ex db IIC T5 Gb
Ex tb IIIC T100°C Db IP66/IP68
-50°C ≤ Ta ≤ +65°C
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db IP66/IP68
-60°C ≤ Ta ≤ +55°C
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db IP66/IP68
-50°C ≤ Ta ≤ +55°C
TYPE 6P, TYPE 4X (UL50E)
IP69 (EN/IEC60529), housing only
IP66/IP67/IP68 (2 hours, 5m (16ft), EN/IEC60529)
MNVCMVXTHD_1813_EN

Publicité

loading

Ce manuel est également adapté pour:

Maximus mvxtMaximus mvxhd