For use in hazardous areas

Attention!
Danger!
Explosion hazard!
Original operating instructions Eccentric worm drive pump F 550 S .... TR and Sanitary pump F 560 S ... TR 31/80
Observe the maximum temperatures:
Liquid temperature [°C]
0 up to 40
> 40 up to 90
Make sure that the operator has read and understood the
operating instructions.
The operator must be instructed on proper use before operating
the pump.
Only use the pump for the intended use.
The pump should n
Never leave the pump unattended.
When using pumps and motors in hazardous areas, do not use
motor adapters.
Only switch the motor on when there is medium on the suction side.
No dry running.
Before you switch on the pump make sure that there is still enough
liquid in the container (dry running).
Observe the EC type examination certificate and the certificate
of conformity, respectively.
The pump must not be used as a stationary unit in hazardous
locations.
Use a motor protection device including a switch lock to prevent au-
tomatic start-up (e.g. by switching on the pump by means of a plug).
In case of automatic filling, a motor with a protective device can also
be used without a switch lock.
For use in hazardous locations only use explosion-proof electric
motors which are approved for category 2 (ZONE 1).
If the motors are operated together with the pump, comprehensive,
clear equipotential bonding is essential (earthing).
Connect the electric motor with an explosion-proof plug or via an
explosion-proof cable terminal box.
For equipotential bonding, an electrically conductive connection
must be produced between the motor and the pump according
to DIN EN 60079-0 and DIN EN 60079-14.
Maximum ambient temperature [°C]
-20 up to 40
T4
T3