Commissioning; Before Starting Operation; Before Starting Operation In Hazardous Areas - FLUX F 550 S TR Serie Notice D'instructions Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.

Commissioning

5.1

Before starting operation

Note
Before the initial start-up, before and after each use we recommend to
clean pump, hose and accessory. Observe chapter "Cleaning".
> Make sure that the supply voltage corresponds to the voltage indicated on the name
plate.
> When using compressed air motors please do not exceed the maximum operating
pressure of 6 bars and use a filter-regulator-lubricator unit.
> When using compressed air motors, adjust the speed by a ball valve in the air supply
line. Slowly bring the air motor to operating speed.
Attention in hazardous areas!
> Before inserting the electrical plug into the socket, ensure that the Start/Stop switch is
set to "0" (Stop). On compressed air motors, close the valve in the air supply line.
> Fasten the pump to the container.
> Immerse the hose end into the container to be filled and secure it there.
5.2

Before starting operation in hazardous areas

Note!
Explosion protection at the connection point is not necessary if
the power socket or the terminal box is clearly located outside the
hazardous area
In order to transfer flammable fluids class IIA and IIB, temperature class T1 to T4, only
use pumps that are approved for use in category 1 (zone 0).
Attention!
Attention!
Attention!
Original operating instructions Eccentric worm drive pump F 550 S .... TR and Sanitary pump F 560 S ... TR 35/80
Information on assembly and disassembly of pump and accessory
you will find in the corresponding chapters.
Observe internal instructions.
Do not exceed the maximum speed of 1,000 rpm
The motor (electrical or driven by compressed air) must not exceed
1.5 kW.
Before each operation check for external damage and smooth
operation.
When using three-phase motors check direction of rotation of the
motor. In case of portable use, check the conformity of phases at
each socket to guarantee always the same direction of rotation.
(Direction of rotation according to the arrow on the bearing flange).
When using the eccentric screw pump, all additional components
(coupling, drive motor, etc.) attached to the connecting part must
be located outside the container.