For use in hazardous areas

! Only use motors which are approved for use in
hazardous areas (ZONE 1).
! Explosion-proof three-phase motors
! Compressed air motors FPM 4 Ex, FPM 6 Ex, FPM 8 Ex
! Observe the EC-Type-Examination Certificate or
the Certificate of Conformity.
! The explosion-proof motor has to be outside the container.
! Only use electrically conductive hoses (see TRbF 131 part 2).
This will provide a conductive path for the pump, hoses and
fittings.
! Only use an explosion-proof plug or an explosion-proof cable
terminal box when making connections to the motor.
! If the electrical socket or the terminal box is positively located
outside of the hazardous area, connection to explosion-proof
equipment must not be undertaken.
Regularly check the motors according to the relevant
national safety regulations and/or rules for prevention
of accidents. (In the Federal Republic of Germany these
are for example BGV A3).
Repairs to three-phase motors should only be carried out
by the manufacturer or an authorized repair shop.
The installation and operation must comply with the relevant
Health & Safety Regulations. (In the Federal Republic of
Germany these are "TRbF" and also "BG Chemie").