The coupling material used (Al or PUR) must not be chemically influenced by the surround-
ing atmosphere.
Explosive atmospheres caused by explosive dusts or unstable substances are excluded
from the application.
The Ex-marking is: II 2 GD IIC TX
Colour coupling insert
red
4.2

Health and safety instructions

Attention in hazardous areas!
If the coupling does not function properly, the operator must stop the pump.
No flame-cutting, welding or cutting work is required for maintenance and inspection.
4.3

Installation and assembly

Secure the motor-side coupling half against axial displacement with a threaded pin
(Mt = 4 Nm). Secure the threaded pin against loosening with an adhesive. The adhesive
must have a temperature resistance of at least 125°C.
Observe the installation instructions for three-phase motors.
Attention in hazardous areas!
4.4

Control, inspection and repair

Eliminate faults immediately by observing the repair instructions.
Pay attention to changed running noises or occurring vibrations during daily checks.
Attention in hazardous areas!
34/80 Original operating instructions Eccentric worm drive pump F 550 S ... TR and Sanitary pump F 560 S ... TR
Minimal surrounding
temperature [Ta]
-20°C
During fault-free operation, the coupling has no effective ignition
sources. The operator ensures trouble-free operation by means of
inspection, maintenance and repair.
Do not carry out maintenance or inspection work on the coupling in
a potentially explosive atmosphere.
Perform comprehensive equipotential bonding on pump and motor.
The sprocket can wear out due to friction, so that the coupling
halves touch each other and ignitable impact sparks could form.
Therefore, check the wear first after ~3,000 hours and again every
3,000 hours or after 6 months at the latest.
Replace the sprocket if wear is visible.
The coupling must be checked by a competent person for correct
installation and faultless function before commissioning and at least
every 3 years.
These checks must be documented.
To maintain the explosion protection concept only the spare parts
specified by the manufacturer may be used
Maximal surrounding
Temperature
temperature [Ta]
class
40°C
T4