Store the device in a dry, clean, frost-free location which is out of the reach of children
and animals. When you do this, place the device upright on its base on a fl at, stable
surface.

Troubleshooting

If the device should stop working properly, fi rst check whether you are able to correct
the problem yourself.
Do not attempt to repair a defective electrical device yourself!
Problem
The device does not
work. The operating
lamp does not light
up / fl ash.
No steam is
produced.
Water emerges from
the bottom of the
iron.
Smoke is emitted
from the device.
The device makes
loud pumping
noises.
25
Possible Cause / Solution
Is the mains plug correctly inserted into the socket?
Is the plug socket defective? Try a different socket and
check the fuse of your mains connection.
Is the water reservoir empty? Refi ll it (see the "Use"
chapter, "Filling the Water Reservoir" section).
The device has not yet reached operating temperature.
Wait until the temperature control lamp lights up
constantly.
Is the temperature control on a low temperature setting?
Select a higher temperature setting.
Is the device upright? Press the
check whether any steam emerges.
If you have set a high temperature, the steam which is
generated is dry and almost invisible. This is exacerbated
by a high ambient temperature. Switch the temperature
control to a lower temperature to check whether the device
is producing steam.
Have you not moved the device for some time? The
automatic safety switch-off function was activated. Take
hold of the handle so that the device switches back on and
heats up again.
Is the water reservoir overfi lled? Pour away some water
(see the "Use" chapter, "After Use" section).
Is the temperature control on a low temperature setting?
Select a higher temperature setting so that steam can be
generated.
You might notice a small amount of smoke the fi rst time
you use the device. However, this is harmless and will
cease as you use the device.
Is the water reservoir empty? Refi ll it (see the "Use" chap-
ter, "Filling the Water Reservoir" section).
steam burst button to
EN