Installation options
The output pressure of 30 mbar (yellow type plate) and
50 mbar (orange type plate) on the gas pressure regu-
lation system must correspond with the operating pressure of
the installed equipment.
Please be sure to note the position of the tank fittings before
installation! Truma has 2 variants (90° and 105°) for instal-
lation with 30 mbar.
90°
Figure 4
The 90° variant is available for 50 mbar.
The MonoControl CS must be installed in such a way that
the triggering element (Figure 5 – A) is always in a vertical
position.
Figure 5
A crash sensor that is not installed vertically cannot be
properly restored to its required original position. This
can lead to false activation.
105°
A
Installation dimensions
A
44
Figure 6 – Dimensions in mm. Not shown to scale
~ 208
15