Technical data
Total contents
Max. spraying pressure
Max. operating temperature
Weight when empty
Material of tank
Where device is carried
Technical residual quantity
Recoil force
Table 1
1. Fasten the carrying strap [6] on the tank [1]. (Fig 2)
2. Screw the spray line [4] tightly into the outlet port [10].
+
Note the location of the spigot in order to be able to insert the lock.
3. Insert the lock [11].
5. Screw the elbow [50] onto the spray wand [7].
Checks
Visual inspection:
spray lance [7] free of damage? (Figures 1, 15)
+
Pay special attention to the connections between the tank – spray line and the spray
No leaks: Pump up the empty device to 2 bar. (29 psi)
Function: Pull the red button on the safety valve [12]. (Fig. 4).
+
Unintentional spraying is prevented after locking. (Fig. 15)
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
3561..
5.0 l (1.32 gal)
9.0 l (2.38 gal)
4.6 kg
.
15
10.0 l (2.64 gal)
13.0 l (3.44 gal)
6 bar (88 psi)
50 °C (122 °F)
Steel
Shoulder
0.03 l (0.008 gal)
1.12 l/min (0.30 gal)
< 5 N
.
.
within 30 minutes.
(Fig. 15)
ENGLISH
3581..
5.2 kg