Rod electrode (MMA) welding
Safety
Tooling up
1.
2.
3.
Selecting the
process
1.
2.
Adjusting wel-
1. Select current using welding current adjuster
ding current,
2. Start welding
igniting the arc
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. You should not use the functions described until you have thoroughly
read and understood the following documents:
-
these operating instructions
-
all the operating instructions for the system components, especially the
safety regulations
WARNING! An electric shock can be fatal. If the machine is plugged into the
mains electricity supply during installation, there is a high risk of very serious
injury and damage. Only carry out work on the machine when
-
the mains switch is in the „O" position,
-
the machine is unplugged from the mains.
Plug the welding cable into current socket, depending upon which type of electrode
is to be used, and latch it by turning it clockwise
Plug the grounding (earthing) cable into the current socket depending upon which
type of electrode is to be used, and latch it by turning it clockwise
Plug in the mains plug
CAUTION! Risk of injury and damage from electric shock. As soon as the
mains switch is in the „I" position, the rod electrode in the electrode holder is
LIVE. Make sure that the rod electrode does not touch any persons or electri-
cally conducting or earthed parts (e.g. the housing etc.)
Move the mains switch to the „I" position
Select one of the following processes using the process button:
The following indicator lights up if the rod electrode (MMA) with rutile electrode
welding process is selected:
The following indicator lights up if the rod electrode (MMA) with basic electrode
welding process is selected:
The following indicator lights up if the rod electrode (MMA) welding with CEL
electrode process is selected:
7