2. 1. 4. Installing the drive/tube assembly
,QVWDOO DQG ¿[ WKH GULYHWXEH DVVHPEO\ RQWR WKH HQG
1)
bracket (f) and onto the drive bracket (g) :
1
(QVXUH WKDW WKH GULYHWXEH DVVHPEO\ LV VHFXUHG RQWR
the end bracket. This operation prevents the drive/
tube assembly from coming out of the end bracket
mounting.
'HSHQGLQJ RQ WKH W\SH RI EUDFNHW ¿W WKH VWRS ULQJ h)
2)
in place.
2. 2. WIRING
The wire between the motor and the power supply must not exceed 8 ft (2,5m) with AWG18
wires.
The motor power supply line must be equipped with a quick disconnect and an over-
current protection.
Cables routed through a metal wall must be protected and insulated by sleeving or
sheathing.
If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then
run the cable in a UV-resistant conduit, e.g. trunking.
Secure the cables to prevent any contact with moving parts.
The cable for the Sunea 40 RTS DC cannot be removed. If it is damaged, return the drive
to the After-Sales department.
1
Leave the drive power supply cable accessible: it must be possible to replace it easily.
1
Always make a loop in the power supply cable to prevent water entering the drive!
Switch off the power supply.
-
Connect the drive according to the information in the table below:
-
2. 2. 1. Sunea 40 RTS DC 03/18 06/18 10/12
1
Blue
2
Brown
2. 2. 2. Only Sunea 40 RTS DC 03/18
The type of power supply must be very low security voltage.
1
Blue
2
Brown
Copyright © 2014 Somfy SAS. All rights reserved.
1
1
12V NiMH battery
2
2
Fuse
230 V
50 Hz
1
Regulated power
1
supply : 12VDC
2
2
Fuse
Images are not contractually binding.
1)
g
2)
h
Battery:
12V solar panel
Output current: 5 A at 12V
(starting current : 7 A during
400 ms with a voltage drop
of 2 V max.)
6 & 10 Nm = 3.15 AT
2
0.75 mm
min.
Power supply's characteristics (Very
Low Security Voltage):
Output voltage between 11,5V and 14V (±0,5V):
Output current: 5 A at 12V (starting current : 7 A
during 400 ms with a voltage drop of 2 V max.)
0.75 mm
2
min.
f
Fuse
3 Nm = 1.6 AT
Fuse
3 Nm = 1.6 AT
3