2. 3. 1. 4. Manual setting for awnings without blocker for up end limit
Move the motor to the desired down end limit position
1)
using the "Down" and "UP" buttons. If you hold the
«UP» or "Down" button for more than 2 seconds
the awning will move automatically in the up or down
direction. You will then have to stop the awning at the
wished end-limit position by pressing the "My" button.
To set the down end limit position, press simultaneously
2)
the "My" and "UP" buttons. The motor will run
automatically in the up direction.
Before the motor reaches the up end limit, press the
3)
"My" button.
If necessary adjust the position with the "UP" or
4)
"Down" buttons.
To set the up end limit position, press simultaneously
5)
the "My" and "Down" buttons. The motor will run
automatically in the down direction.
Press "My" to stop the motor.
6)
7R FRQ¿UP WKH HQG OLPLWV SUHVV IRU  VHFRQGV RQ "My"
7)
until the motor jogs.
The operation is completed. Go to section 2.3.2.
If you do not want to use this transmitter as the individual control, switch the power supply
off (2 seconds minimum).
2. 3. 2. 3URJUDPPLQJ WKH ¿UVW LQGLYLGXDO FRQWURO SRLQW
1
This operation can only be performed from the
transmitter that was used for operation 2.3.1.1.
Press the transmitter "Prog." button for approximately
-
1 second. The motor will jog in both direction.
The operation is completed.
Your transmitter is now programmed to control the motor
in stable mode.
2. 3. 3. Programming/adding a new (individual, group, or main) control point
Open the memory of the motor from the individual
1)
control transmitter:
Press the "Prog." button of the transmitter for about 3
-
seconds until the motor jogs in both directions.
&RQ¿UP WKH RSHUDWLRQ IURP WKH QHZ WUDQVPLWWHU \RX
2)
wish to add:
Press the "Prog." button of the transmitter less than 1
-
second. The motor will jog in both directions.
The operation is completed.
For group controls, repeat operations 1 and 2 for each
-
motor in the group.
For general controls, repeat operations 1 and 2 for
-
each motor in the installation.
To delete a transmitter from the memory of a motor,
-
perform operations 1 with a programmed transmitter,
then perform the operation 2 with the transmitter to
be deleted
Copyright © 2014 Somfy SAS. All rights reserved.
1)
3)
0.5 s
5)
0.5 s
7)
Adding
1)
PROG. a
3 s
Deletion
1)
PROG. a
3 s
Images are not contractually binding.
2)
0.5 s
4)
6)
0.5 s
2.3.2
2 s
PROG. 1 s.
2)
PROG. b
1 s
2)
PROG. b
1 s
5