2.1.4. Mounting the tube-drive assembly
Fit and attach the tube-drive assembly to the end
1)
support
and the drive support
f
Make sure that the tube-drive assembly is locked
in place on the end support. This prevents the tube-
drive assembly from coming out of the end support
fixing.
Depending on the type of support, fit the retaining ring
2)
in place.
h
2.2. WIRING
Respect Standard NF C 15-100 regarding the electrical installations.
Cables routed through a metal wall must be protected and insulated by sleeving or sheathing.
Secure the cables to prevent any contact with moving parts.
If the drive is used outdoors and if the power supply cable is of the H05-VVF type,
run the cable in a UV-resistant duct, e.g. trunking.
The cable of the S&SO-RS100 io is removable. If it becomes damaged, replace it with
an identical cable.
Leave the drive power supply cable accessible: it must be easily replaceable.
Always make a loop in the power supply cable
to prevent water from entering the drive!
The S&SO-RS100 io is a Category II drive and has
no earth wire.
Switch the power supply off.
-
Connect the drive according to the information provided
-
in the table below:
Cable
Blue
N
Brown
L
2.3. SET-UP
This guide describes set-up using a Somfy Smoove io type io-homecontrol
Identifying the steps to be performed
The settings for the end limits depend on the type of roller shutter:
40
:
g
230 V 50 Hz
Neutral
Phase
Copyright © 2014 - 2017 SOMFY ACTIVITES SA. All rights reserved.
1)
g
2)
h
OFF
230 V
50 Hz
L
N
N
L
local control point.
®