ILMO 2 40 WT
2. 1. 4. Installing the drive/tube assembly
Install and fix the tube/drive assembly onto the end bracket
1)
f and onto the drive bracket g:
Ensure that the drive/tube assembly is secured onto the
end bracket. This operation prevents the drive/tube
assembly from coming out of the end bracket mounting
when the roller blind reaches the lower end limit position.
Depending on the type of bracket, screw the adapter
2)
onto the motor head.
2. 2. WIRING
Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then run the
cable in a UV-resistant conduit, e.g. trunking.
The cable for the Ilmo 2 40 WT cannot be removed. If it is damaged, return the drive to the After-
Sales department.
Leave the drive power supply cable accessible: it must be
possible to replace it easily.
Always make a loop in the power supply cable to prevent
water entering the drive!
The ILMO 2 40 WT is a Class II drive; it has no earth wire.
Switch off the power supply.
-
Connect the drive according to the information in the table
-
below:
230 V
50 Hz
it is possible to wire several motors to the same control point by following the formula:
Number of motors which can
be connected in parallel
Copyright © 2018 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
Cable
Neutral (N)
Live (L1)
Blue
Brown
Cut-off power of the control point
≤
Rated current (A)
(see technical datasheet)
Live (L2)
Black
(A) x 0.7
1)
g
2)
h
OFF
N
L1
L2
230 V
50 Hz
EN
f
15