Insert function
Time
During the normal operation, the data transmission happens to regular intervals of time.
To turn on the radiocomando to press the key P3 with the visualization of the state of the insert with some second of
delay.
To press the key P4 to access the menu, P5 to activate the function, P1 and P2 for the choice of the parameter.
Following the available functions are listed:
- BACK ILLUMINATION (adjustable duration from 2 to 10 sec)
- POWER ON (Time ON of the radicomando)
- BRIGHTNESS' (ON. OFF)
- CONTRASTt (Regulation contrast)
- BUZZER (I Play to the pressure of the keys of the radiocomando)
4.2.1
Lighting
Before lighting the stove:
make sure to have read and understood the instructions in the manual;
the hopper must be filled with pellets;
the combustion chamber must be clean;
the brazier must be completely free, clean of any combustion residuals and properly positioned in the
brazier holder;
check the hermetic closure of the fire door and ash pan;
make sure the stove is completely inserted in its compartment and that it is properly electrically powered.
- At first lighting, remove any components that could burn (instructions/label) from the insert firebox.
- Any lightings done after long unit idle periods require the renewal of any pellets that have been inside the hopper
for a long time (in being a damp fuel no longer suitable for combustion) and complete cleaning of the combustion
chamber.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Center.
To light the stove press button P3 on the remote control. The message START will appear on the LCD display. This
phase is automatic and is managed entirely by the electronic control, without any possibility of changing the
parameters.
The stove carries out the startup phases in sequence according to the procedure defined by the parameters. If the
fume temperature has not reached the minimum permissible value, the stove goes in alarm status. If the
temperature is reached, after a certain time, the insert goes in work status.
4.2.2
Work phase
After the startup phase, the insert goes to WORK mode, which is normal operation.
Pressing the button P1 of the radiocomando the power can be planned by the value min of 1 to a value max of 5;
pressing the button instead P2 the Set of the temperature of the water can be planned (40 - 80°C) ;
pressing in continue the button P2 and P5 the Set of the temperature environment can be planned by a value min
of 7 °C to a maximum value of 40 °C.
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of fuel.
- Make sure the unit is off when loading pellets.
- The pellet hopper cover must always remain closed, to be opened only during fuel loading.
- The bags of pellets must be kept at least 1.5 m from the insert.
If the STANDBY mode is not activated and the set temperature is reached, or if the fume temperature has reached
the set maximum value, the LCD display shows the message MODULATE or MODULATE F and the stove activates
the flame modulation procedure without any intervention by the user.