3.8 Fume extractor fan failure
If the fume extractor fan stops for any reason, the electronic controller instantly stops the pellet feed, displaying the
message 'AL 4 FAN FAIL'.
3.9 Pellet hopper – fire door safety
The safety microswitch intervenes when the pellet tank door or fire dore is opened during the normal operations of
the product. In such case the motherboard will stop immediately the pellet loading and the message AL 8 NO
DEPRESSURE will be displayed within seconds.
4 STOVE USE
The stove has the advantage of combining heat from a wood flame with the convenience of automatic control of
temperature and the possibility of programming lighting and shutdown.
4.1 Introduction
For safe and reliable use:
when lighting the first time, unpleasant odors may be created, therefore ensure good ventilation of the room,
especially during the first period of operation;
the hopper must only be filled with pellets; make sure the bag does not come into contact with the hot
surfaces of the insert;
do not put any type of fuel other than recommended wood pellets in the hopper;
the unit must not be used as a waste incinerator;
the insert must work only and exclusively with the fire door always closed;
the fire door seals should be checked periodically to ensure air tightness;
to ensure efficient and correct operation, it is necessary to clean the brazier whenever pellets are loaded;
when lighting the insert for the first time, make sure to allow it to get hot gradually without overheating;
during lighting, operation and shutdown, the insert may creak a little due to the heat expansion.
The insert is operated using a remote control provided with seven buttons and an LCD display. The remote control
enables insert lighting and shutdown, adjustment during operation and the setting of management programs.
The insert also has a button control panel, which can be used instead of the remote control if necessary, allowing
only some functions.
Given fig. 4.1 – 4.2 is the radio remote control and control panel with the main functions of the buttons.
4.2 Use via remote control
The remote control is a device that transmits via radio waves, therefore it does not have to be pointed at the
receiver unit in the control panel.
In an open space, the remote control operating range is over 10 meters. In the presence of walls or other obstacles,
the range can be reduced by a few meters.
Before using the remote control it is necessary to carry out tuning with the electronic board of the insert. This may
be necessary at first activation or when the data communication channel between the board and remote control is
interrupted. In this case, the display will show the message SEARCHING FIELD. The tuning operation may also be
required when there are other appliances which create interference with the insert.
To carry out this operation, proceed as follows:
Disconnect the stove power supply.
Press buttons P3 and P5 at the same time. The message RADIO ID 0#. will appear. With the scroll buttons
select NEW UNIT' and confirm with buttons P5.
Select the ID value with the P1 and P2 buttons from 0 to 64 (default ID = 0).
Connect the stove power supply.
Within 10 seconds after turning on the power, confirm the selected channel by pressing button P5.
The message UNIT LOADED and then stove status will appear in quick succession while the emergency
LEDs remain stationary for a short time in confirmation of acquisition.
If the message SEARCHING FIELD appears, tuning was unsuccessful and the procedure must be
repeated.
The remote controller display changes according to the status of the insert, or the menu displayed. When idle, the
display shows the following items: