Work Phase - Anselmo Cola SWING Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.2.1
Lighting
Before lighting the insert:
make sure to have read and understood the instructions in the manual;
the hopper must be filled with pellets;
the combustion chamber must be clean;
the brazier must be completely free, clean of any combustion residuals and properly positioned in the
brazier holder;
check the hermetic closure of the fire door and ash pan;
make sure the insert is completely inserted in its compartment and that it is properly electrically powered.
- At first lighting, remove any components that could burn (instructions/label) from the insert firebox.
- Any lightings done after long unit idle periods require the renewal of any pellets that have been inside
the hopper for a long time (in being a damp fuel no longer suitable for combustion) and complete
cleaning of the combustion chamber.
To light the insert press button P3 on the remote control. The message START will appear on the LCD display. This
phase is automatic and is managed entirely by the electronic control, without any possibility of changing the
parameters.
The insert carries out the startup phases in sequence according to the procedure defined by the parameters. If the
fume temperature has not reached the minimum permissible value, the insert goes in alarm status. If the
temperature is reached, after a certain time, the insert goes in work status.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Center.
4.2.2

Work phase

After the startup phase, the insert goes to WORK
mode, which is normal operation.
The heating power can be adjusted with the remote
control. By pressing button P5 the display appears as
shown opposite.
Press P1 and P2 to set the power from a minimum
value of 1 to a maximum value of 5.
Using the remote control it is also possible adjust the room temperature. Press button P4 and
the display appears as shown opposite.
Then press buttons P1 and P2 to set the room temperature, from a minimum value of 7°C to a
maximum value of 40°C.
The insert automatically adjusts the ventilation of hot air according to the current work phase.
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of fuel.
- Make sure the unit is off when loading pellets.
- The pellet hopper cover must always remain closed, to be opened only during fuel loading.
- The bags of pellets must be kept at least 1.5 m from the insert.
Using the remote control it is also
possible
adjust
temperature. Press button P4 and
the
display
appears
opposite.
Then press buttons P1 and P2 to set
the
room
temperature,
minimum value of 7°C to a maximum
value of 40°C.
39
the
room
as
shown
from
a
SWING

Publicité

Table des Matières
loading

Table des Matières