Mise en service et paramétrage
Exemple de protocole de paramètres
Fig. 112
Protocole de paramétrage MCU (exemple)
Device Type: MCU
Mounting Location: SICK
Device Information
Device Type
Serial Number
Ident Number
System Time
Firmware Version
Hardware Version
Bootloader Version
Calculation Values
Sources
Temperature Source
Pressure Source
Moisture Source
Constants
Temperature Constant
Pressure Constant
Moisture Constant
Adjustment
Function Check Interval
Function Check Output Duration
Output Check Results on AO
System Configuration
Number of external AO
Number of external AI
Serial Expansion Module
Serial Expansion Module
Type
Profibus Address
Modbus Address
IP Address
Subnet Mask
Gateway
TCP Port
7/22/14 10:56 AM
FLOWSIC100 · Manuel d'utilisation · 8012724/10LA/V 2-2/2019-02 · © SICK Engineering GmbH
MCU Parameter Protocol - FL100 2 Path
I/O Configuration
MCU
Analog Output General Settings
00004711
Error Current Selection
00000
Error Current Value
08 Nov 2009
Maint. Current Selection
22:03:46
Maint. Current Value
01.08.00
Span Value
1.5
Analog Output 1
00.99.xx
Live Zero
Limit Low
Limit High
Calibration factor CC0
Analog Input 1
Calibration factor CC1
Calibration factor CC2
Analog Input 2
Constant Value
Source
Analog Output 2
20.00°C
Live Zero
Limit Low
1013.25mbar
50.00%
Limit High
Source
Analog Output 3
8 hours
90s
Live Zero
Limit Low
yes
Limit High
Source
Analog Output 4
0
Live Zero
0
Limit Low
Ethernet
Limit High
Source
Analog Output 5
Ethernet 10BaseT
Live Zero
126
Limit Low
1
Limit High
010.133.082.001
Source
255.255.248.000
Analog Input 1 (Temperature)
000.000.000.000
Limit Low
2111
Limit High
Calibration factor CC0
Calibration factor CC1
Calibration factor CC2
Analog Input 2 (Pressure)
Limit Low
Limit High
Calibration factor CC0
Calibration factor CC1
Calibration factor CC2
Analog Input 3 (Moisture)
Limit Low
Limit High
Limit Switch
Source
Limiting Value
T90 Time
T90 Time FL Path 1
T90 Time FL Path 2
yes
21 mA
User defined value
0.50mA
70%
4mA
0.50
1.87
0.0000
171.0000
0.0000
Velocity of Gas (avg)
4mA
-100.00
100000.00
Volume flow s.c. dry
(avg)
4mA
-20.00
20.00
Velocity of Gas (avg)
4mA
0.00
1.00
Not Used
4mA
0.00
1.00
Not Used
0.00°C
200.00°C
0.0000
0.0204
0.0000
0.00mbar
1100.00mbar
0.0000
0.0204
0.0000
0.00%
0.00%
Velocity of Gas (avg)
1.87
1.0s
1.0s
Page 1/1
137