3.2.5. Operation in sequential mode with automatic
closing after time delay
The gate is automatically closed after a time-delay programmed during
installation.
A new command sent during this time-delay cancels automatic closing
and the gate remains open.
The subsequent command causes the gate to close.
3.2.6. Operation using the backup battery
If a backup battery is installed, the motorisation will work even during a
power outage.
Operation is then activated under the following conditions:
• Reduced and constant speed.
• The additional devices (photoelectric cells, orange light, wired code
keypad, etc.) do not operate.
Battery specifications:
• Battery life: 24 hrs; 3 operating cycles depending on the weight of
the gate.
• Recharging time: 48 hours
• Service life before replacement: Approximately 3 years.

3.3. Adding remote controls

3.3.1. Keygo io
This operation is used to copy the function of a button on a memorised
Keygo io remote control to a button on a new Keygo io remote control.
1)
Keygo io A
A
Keygo io B
3)
B
2s
Remote control "A" = "source" remote control already memorised
Remote control "B" = "target" remote control to be memorised
For example, if the button on remote control A opens the gate fully, the
button on the new remote control B will also open the gate fully.
4

3.4. Emergency manual release

1) Insert the key into the lock.
2) Turn the key a quarter of a turn to the left.
3) Turn the release handle to the right.

3.5. Locking the motorisation

1) Turn the release handle to the left.
2) Move the gate manually until the drive mechanism locks.
2)
3)
2s
3) Turn the key a quarter of a turn to the right.
4) Remove the key.
4)

4. MAINTENANCE

4.1. Checks

4.1.1. Safety devices (cells, safety edge)
Check for correct operation every 6 months.
4.1.2. Backup battery
For optimum battery life, it is recommended that the main power supply be
switched off and the motor operated using the battery for several cycles,
three times a year.

4.2. Replacing the battery

Attention
Do not forcibly push the gate. Hold the gate over its entire travel
during manual manoeuvres.
[1]
4)
[2]
Attention
The motorisation must be locked before a new command.