will be counted down to zero. This countdown can be ac-
knowledged and canceled at any time by the STOP/RESET
key. However, note that for that time the pipe fitting joint
which is still warm must not be subjected to an external
force. No cooling time is displayed if the fitting code does
not contain any such information.

5.11 Returning to the Start of Parameter Input

After welding is finished, disconnecting the welded fitting
from the unit or pressing the STOP/RESET key will reset the
unit back to the start of entering the welding parameters.
5.12 Using ViewWeld to Manage Logged Welding
Reports, Print Tags, and Assign Geo-data
The ViewWeld feature offers viewing an abstracted ver-
sion of the welding reports recorded during the welding
processes and printing it as a label tag to be affixed to the
joint on the optionally available tag printer. The ViewWeld
abstract shows the report number, the date and time of
the welding and the welding parameters along with an
evaluation of the quality of the joint/welding operation
(see Display 6), where the first displayed abstract is that
of the last performed welding operation.
To call the ViewWeld abstract of a welding report, press the
ñ key in the bar code input screen (see Display 2). Browsing
through the saved welding reports is then possible by press-
ing the ï or ð cursor keys. To print a tag of the welding
operation of which the abstract is currently displayed, the
label tag printer has to be connected to the welder. Then
press the START/SET key in the ViewWeld screen.
ViewWeld also enables assigning the geo-data of a joint
after it was made, in case they were not recorded with
enabled geo-data logging at the welding operation (see
Sect. 6.7). To do this, call the ViewWeld screen and, if
needed, browse to the welding abstract of the joint that
needs to have its geo-data assigned. Then press the ñ
cursor key in the ViewWeld screen displaying the desired
welding operation. This causes a screen asking you if you
want to record geo-data to appear (see Display 12). Con-
firm by pressing the START/SET key and log the geo-data
according to the procedure described in Sect. 6.7.
6

Additional Information in the Welding Report

Every welding report saved to system memory, which can
be downloaded as a PDF report file or in the DataWork
Version August 2016
HÜRNER HST 300 Print + 2.0 User's Manual
0015
24.02.13 09:33
M/B
MON HST
315
0058s
025.0V
1.57Ω
Welding OK
Display 6
EN
13