H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
and ò arrow keys can be used to select from the commis-
sions currently in system memory the desired one, of which
the reports should be downloaded, or the alphanumeric
keypad can be used (see Info in Sect. 5.2) to enter a start
date and an end date, or the first and the last report, that
define a range of dates or a range of reports of which the
reports should be downloaded. When you press the START/
SET key, you cause the selected reports to be transferred
to the storage media.

8.4 Understanding the Report Download Process

The download starts automatically after a selection was
made among the options. Wait for all the selected reports
to transfer and the "Download completed" message to
appear on the screen.
If a problem occurs while the download is in progress, a
"Not ready" message shows. After the problem condition
is cleared, the download resumes automatically.
If the welding unit recognizes a problem that
cannot be cleared while the data transfer is in
Info
progress, it does not resume the process and dis-
plays a "Download cancelled" error message. To
acknowledge this error, press the START/SET key.

8.5 Deleting Data from Memory

The report data in memory can be deleted only after all
welding reports were transferred, which is indicated by the
"Download completed" message. When the storage media
is unplugged, a "Delete Memory" message appears. If the
START/SET key is pressed at this point, a further confirma-
tion message "Delete Memory, sure?" is shown, which has
to be confirmed by pressing the START/SET key once again.
Then, the report data in memory are deleted.

8.6 Keeping Data in Memory

When the cable or storage media is unplugged, a "Delete
Memory" message is displayed. Press the STOP/RESET key
to keep the current report data in memory. They can then
be printed off once again.
Make a habit of handling the internal storage as
described at the beginning of Sect. 8, to maintain
data integrity and avoid any inadvertent deletion
Important
of the reports in memory.
Version August 2016